Domestic fan EC010004

Features 39

  1. 1

    Housing materialEF001596

    Choose one value

    SteelPlasticOther
  2. 2

    Max. air volume at 50 PaEF014851

    A number in m³/h

  3. 3

    Max. air volume at 100 PaEF014959

    A number in m³/h

  4. 4

    Max. air volume at 150 PaEF014960

    A number in m³/h

  5. 5

    Max. air volume at 200 PaEF014961

    A number in m³/h

  6. 6

    Max. air volume at 250 PaEF014962

    A number in m³/h

  7. 7

    Max. air volume at 300 PaEF014963

    A number in m³/h

  8. 8

    Power input according to EPN standardEF024359

    A number in kW

  9. 9

    Cos phi according to EPN standardEF024360

    A number

  10. 10

    Type of motorEF002735

    Choose one value

    ACDCElectronically commutated (EC)Other
  11. 11

    Electrical connectionEF003701

    Choose one value

    CableConnecting cable with plug with protective contactPerilex connecting cableTerminalsOther
  12. 12

    Energy efficiency classEF000758

    Choose one value

    A++A+ABCDEFGOther
  13. 13

    Control signalEF000513

    Choose one value

    0 - 10 VPWM (pulse-width-modulated)Other
  14. 14

    Type of speed controlEF020120

    Choose one value

    3 positionsContinuously variableOther
  15. 15

    With wireless remote controlEF021154

    Yes or no

    YesNo
  16. 16

    Suitable for wireless remote controlEF024361

    Yes or no

    YesNo
  17. 17

    With wired control unitEF014706

    Yes or no

    YesNo
  18. 18

    Suitable for wired control unitEF014707

    Yes or no

    YesNo
  19. 19

    Suitable for requirement-controlled ventilationEF024375

    Yes or no

    YesNo
  20. 20

    With internal humidity (RH) sensorEF014700

    Yes or no

    YesNo
  21. 21

    With external humidity (RH) sensorEF014701

    Yes or no

    YesNo
  22. 22

    Suitable for (extra) humidity (RH) sensorEF014702

    Yes or no

    YesNo
  23. 23

    With internal carbon dioxide (CO2) sensorEF013630

    Yes or no

    YesNo
  24. 24

    With external carbon dioxide (CO2) sensorEF014698

    Yes or no

    YesNo
  25. 25

    Suitable for (extra) carbon dioxide (CO2) sensorEF014699

    Yes or no

    YesNo
  26. 26

    With pressure sensorEF013644

    Yes or no

    YesNo
  27. 27

    Suitable for (extra) pressure sensorEF014703

    Yes or no

    YesNo
  28. 28

    With zone controllerEF014708

    Yes or no

    YesNo
  29. 29

    Suitable for zone controllerEF014709

    Yes or no

    YesNo
  30. 30

    Operation by appEF012384

    Yes or no

    YesNo
  31. 31

    With movement sensorEF000197

    Yes or no

    YesNo
  32. 32

    Suitable for movement sensorEF001193

    Yes or no

    YesNo
  33. 33

    Nominal duct diameterEF020311

    A number in mm

  34. 34

    ConnectionEF000443

    Choose one value

    Insert endDuct endOther
  35. 35

    Number of suction connectionsEF022078

    A number

  36. 36

    Rear connectionEF022079

    Yes or no

    YesNo
  37. 37

    DepthEF000049

    A number in mm

  38. 38

    HeightEF000040

    A number in mm

  39. 39

    WidthEF000008

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.