MEV Unit EC010004
Features 50
- 1
Housing MaterialEF001596
Choose one value
SteelPlasticOther - 2
Max. Air Volume at 50 PaEF014851
A number in m³/h
- 3
Max. Air Volume at 100 PaEF014959
A number in m³/h
- 4
Max. Air Volume at 150 PaEF014960
A number in m³/h
- 5
Max. Air Volume at 200 PaEF014961
A number in m³/h
- 6
Max. Air Volume at 250 PaEF014962
A number in m³/h
- 7
Max. Air Volume at 300 PaEF014963
A number in m³/h
- 8
Power Consumption at Max. Air Volume at 100 PaEF017599
A number in kW
- 9
Frequency supply voltageEF004687
A range, from and to, in Hz
- 10
Supply voltageEF004127
A range, from and to, in V
- 11
Max. nominal currentEF009326
A number in A
- 12
Sound performance levelEF002270
A number in dB(A)
- 13
Type of MotorEF002735
Choose one value
ACDCElectronically commutated (EC)Other - 14
Electrical ConnectionEF003701
Choose one value
CableRA-plug connecting cordPerilex connecting cordTerminalsOther - 15
Energy efficiency classEF000758
Choose one value
A++A+ABCDEFGOther - 16
Control signalEF000513
Choose one value
0-10 VPWMOther - 17
Type of Speed ControlEF020120
Choose one value
3 settingsContinuously variableOther - 18
With Wireless Remote ControlEF021154
Yes or no
YesNo - 19
Suitable for Wireless Remote ControlEF024361
Yes or no
YesNo - 20
With Wired Control UnitEF014706
Yes or no
YesNo - 21
Suitable for Wired Control UnitEF014707
Yes or no
YesNo - 22
Suitable for requirement-controlled ventilationEF024375
Yes or no
YesNo - 23
With Internal Humidity (RH) SensorEF014700
Yes or no
YesNo - 24
With External Humidity (RH) SensorEF014701
Yes or no
YesNo - 25
Suitable for (extra) Humidity (RH) SensorEF014702
Yes or no
YesNo - 26
With Internal Carbon Dioxide (CO2) SensorEF013630
Yes or no
YesNo - 27
With external carbon dioxide (CO2) sensorEF014698
Yes or no
YesNo - 28
Suitable for (extra) Carbon Dioxide (CO2) SensorEF014699
Yes or no
YesNo - 29
Detect volatile organic compounds (VOC)EF025514
Yes or no
YesNo - 30
With pressure sensorEF013644
Yes or no
YesNo - 31
Suitable for (extra) pressure sensorEF014703
Yes or no
YesNo - 32
With Zone ControllerEF014708
Yes or no
YesNo - 33
Suitable for Zone ControllerEF014709
Yes or no
YesNo - 34
Operation by AppEF012384
Yes or no
YesNo - 35
With movement sensorEF000197
Yes or no
YesNo - 36
Suitable for movement sensorEF001193
Yes or no
YesNo - 37
Air flow sensor controlledEF018161
Yes or no
YesNo - 38
Nominal duct diameterEF020311
A number in mm
- 39
ConnectionEF000443
Choose one value
Insert endDuct endOther - 40
Number of suction connectionsEF022078
A number
- 41
Suitable for Wall MountingEF000664
Yes or no
YesNo - 42
Suitable for Ceiling MountingEF021180
Yes or no
YesNo - 43
Suitable for floor mounting (no longer used)EF007243
Yes or no
YesNo - 44
Suitable for suspended mountingEF001265
Yes or no
YesNo - 45
Mounting horizontalEF006051
Yes or no
YesNo - 46
Mounting method, verticalEF024092
Yes or no
YesNo - 47
Rear connectionEF022079
Yes or no
YesNo - 48
DepthEF000049
A number in mm
- 49
HeightEF000040
A number in mm
- 50
WidthEF000008
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.