Domestic fan EC010004

A ventilation device used in residential settings to improve air circulation.

Features 71

  1. 1

    Housing materialEF001596

    Choose one value

    SteelPlasticOther
  2. 2

    Max. air volume at 50 PaEF014851

    A number in m³/h

  3. 3

    Max. air volume at 100 PaEF014959

    A number in m³/h

  4. 4

    Max. air volume at 150 PaEF014960

    A number in m³/h

  5. 5

    Max. air volume at 200 PaEF014961

    A number in m³/h

  6. 6

    Max. air volume at 250 PaEF014962

    A number in m³/h

  7. 7

    Max. air volume at 300 PaEF014963

    A number in m³/h

  8. 8

    Power consumption at max. air volume at 100 PaEF017599

    A number in W

  9. 9

    Supply voltage frequencyEF004687

    A range, from and to, in Hz

  10. 10

    Voltage ratingEF004127

    A range, from and to, in V

  11. 11

    Max. nominal currentEF009326

    A number in A

  12. 12

    Sound performance levelEF002270

    A number in dB(A)

  13. 13

    Type of motorEF002735

    Choose one value

    ACDCElectronically commutated (EC)Other
  14. 14

    Electrical connectionEF003701

    Choose one value

    CableConnection cable with europlugConnecting cable with plug with protective contactPerilex connecting cableTerminalsOther
  15. 15

    Extra electrical connection included separatelyEF018844

    Choose one value

    Connecting cable with plug with protective contactConnection cable with europlugPerilex connecting cableOther
  16. 16

    Energy efficiency classEF000758

    Choose one value

    A++A+ABCDEFGOther
  17. 17

    Control signalEF000513

    Choose one value

    0 - 10 VPWM (pulse-width-modulated)Other
  18. 18

    Type of speed controlEF020120

    Choose one value

    3 positionsContinuously variableOther
  19. 19

    Type of switchEF003496

    Choose one value

    Push buttonTwo-way switchOther
  20. 20

    With wireless remote controlEF021154

    Yes or no

    YesNo
  21. 21

    Suitable for wireless remote controlEF024361

    Yes or no

    YesNo
  22. 22

    With wired control unitEF014706

    Yes or no

    YesNo
  23. 23

    Suitable for wired control unitEF014707

    Yes or no

    YesNo
  24. 24

    Suitable for requirement-controlled ventilationEF024375

    Yes or no

    YesNo
  25. 25

    With internal humidity (RH) sensorEF014700

    Yes or no

    YesNo
  26. 26

    With external humidity (RH) sensorEF014701

    Yes or no

    YesNo
  27. 27

    Suitable for (extra) humidity (RH) sensorEF014702

    Yes or no

    YesNo
  28. 28

    With internal carbon dioxide (CO2) sensorEF013630

    Yes or no

    YesNo
  29. 29

    With external carbon dioxide (CO2) sensorEF014698

    Yes or no

    YesNo
  30. 30

    Suitable for (extra) carbon dioxide (CO2) sensorEF014699

    Yes or no

    YesNo
  31. 31

    Detect volatile organic compoundsEF025514

    Yes or no

    YesNo
  32. 32

    With pressure sensorEF013644

    Yes or no

    YesNo
  33. 33

    Suitable for (extra) pressure sensorEF014703

    Yes or no

    YesNo
  34. 34

    With constant volume flow controlEF014957

    Yes or no

    YesNo
  35. 35

    With zone controllerEF014708

    Yes or no

    YesNo
  36. 36

    Suitable for zone controllerEF014709

    Yes or no

    YesNo
  37. 37

    Operation by appEF012384

    Yes or no

    YesNo
  38. 38

    With motion sensorEF000197

    Yes or no

    YesNo
  39. 39

    Suitable for motion sensorEF001193

    Yes or no

    YesNo
  40. 40

    Sensor controlled air flowEF018161

    Yes or no

    YesNo
  41. 41

    Number of suction connectionsEF022078

    A number

  42. 42

    Number of sanitary connectionsEF019356

    A number

  43. 43

    Number of kitchen connectionsEF019357

    A number

  44. 44

    Max. number of wet zonesEF019346

    A number

  45. 45

    ConnectionEF000443

    Choose one value

    Insert endDuct endOther
  46. 46

    Nominal duct diameter, suction sideEF024510

    A number in mm

  47. 47

    Nominal duct diameter exhaust airEF019360

    A number in mm

  48. 48

    Nominal duct diameter sanitary connectionsEF019358

    A number in mm

  49. 49

    Nominal duct diameter kitchen connectionsEF019359

    A number in mm

  50. 50

    Number of ventilation valves includedEF019355

    A number

  51. 51

    Suitable for wall mountingEF000664

    Yes or no

    YesNo
  52. 52

    Suitable for ceiling mountingEF021180

    Yes or no

    YesNo
  53. 53

    Suitable for mounting in suspended ceilingEF019477

    Yes or no

    YesNo
  54. 54

    Suitable for mounting in an atticEF019478

    Yes or no

    YesNo
  55. 55

    Suitable for floor mountingEF025108

    Yes or no

    YesNo
  56. 56

    Suitable for suspended mountingEF001265

    Yes or no

    YesNo
  57. 57

    Horizontal mountingEF006051

    Yes or no

    YesNo
  58. 58

    Vertical mountingEF024092

    Yes or no

    YesNo
  59. 59

    Rear connectionEF022079

    Yes or no

    YesNo
  60. 60

    DepthEF000049

    A number in mm

  61. 61

    HeightEF000040

    A number in mm

  62. 62

    WidthEF000008

    A number in mm

  63. 63

    WeightEF000167

    A number in kg

  64. 64

    Suitable for a one-room dwelling acc. to decree nr. 87-149 and law 96-1107EFFR0017

    Yes or no

    YesNo
  65. 65

    Suitable for a two-room dwelling acc. to decree nr. 87-149 and law 96-1107EFFR0018

    Yes or no

    YesNo
  66. 66

    Suitable for a three-room dwelling acc. to decree nr. 87-149 and law 96-1107EFFR0019

    Yes or no

    YesNo
  67. 67

    Suitable for a four-room dwelling acc. to decree nr. 87-149 and law 96-1107EFFR0020

    Yes or no

    YesNo
  68. 68

    Suitable for a five-room dwelling acc. to decree nr. 87-149 and law 96-1107EFFR0021

    Yes or no

    YesNo
  69. 69

    Suitable for a six-room dwelling acc. to decree nr. 87-149 and law 96-1107EFFR0022

    Yes or no

    YesNo
  70. 70

    Suitable for a seven-room dwelling acc. to decree nr. 87-149 and law 96-1107EFFR0023

    Yes or no

    YesNo
  71. 71

    Weighted average power according to RT 2005EFFR0027

    A number in W-Th-C

Codes after each name are ETIM feature codes. Use them, not the names, in product data.