Flue gas roof duct EC010110

Features 27

  1. 1

    System type (no longer used)EF020381

    Choose one value

    Single-walledDouble-walledParallelConcentric
  2. 2

    Max. medium temperature (continuous)EF020023

    A number in °C

  3. 3

    Diameter of single-walled systemEF024132

    A number in mm

  4. 4

    Inner diameter of double-walled systemEF024135

    A number in mm

  5. 5

    Diameter of parallel systemEF022689

    Choose one value

    60 / 60 mm80 / 80 mm100 / 100 mm (no longer used)130 / 130 mm150 /150 mmOther
  6. 6

    Diameter of concentric systemEF022688

    Choose one value

    60 / 100 mm70 / 110 mm80 / 110 mm80 / 125 mm100 / 150 mm110 / 150 mm130 / 180 mm130 / 200 mm150 / 200 mmOther
  7. 7

    Positive (overpressure)EF024123

    Yes or no

    YesNo
  8. 8

    Wet (condensing)EF024124

    Yes or no

    YesNo
  9. 9

    Negative (negative pressure)EF024125

    Yes or no

    YesNo
  10. 10

    Dry (non-condensing)EF024126

    Yes or no

    YesNo
  11. 11

    Flue materialEF024312

    Choose one value

    Stainless SteelAluminiumSteelPlasticOther
  12. 12

    Air supply pipe materialEF024313

    Choose one value

    Stainless SteelAluminiumSteelPlasticCopperOther
  13. 13

    Flue quality classEF024314

    Choose one value

    Cor-Ten steelStainless steel 316 (1.4401)Stainless steel 304 (1.4301)Stainless steel 316 L (1.4404)Stainless steel 316 Ti (1.4571)Al 99.0 (3.0205)Al 99.5 (3.0255)AlMgSi 0.5 (3.3206)PP (no longer used)PP, not readily flammable
  14. 14

    With sliding plateEF024326

    Yes or no

    YesNo
  15. 15

    Sliding plate modelEF025219

    Choose one value

    StandardFlexibleOther
  16. 16

    Flue surface protectionEF024315

    Choose one value

    NoneGalvanic/electrolytic zinc platedHot Dip GalvanizedSendzimir galvanizedOther
  17. 17

    Air supply pipe surface protectionEF024316

    Choose one value

    NoneGalvanic/electrolytic zinc platedHot Dip GalvanizedSendzimir galvanizedCoatedCopper-platedOther
  18. 18

    Air supply pipe surface treatmentEF024317

    Choose one value

    NonePickledPolishedOther
  19. 19

    Icicle/icing-freeEF024136

    Yes or no

    YesNo
  20. 20

    With mechanical ventilation connectionEF024137

    Yes or no

    YesNo
  21. 21

    Diameter of mechanical ventilation connectionEF024138

    A number in mm

  22. 22

    Colour on the roofEF024139

    Choose one value

    NoneWhiteCreamBlackGreyAnthraciteRedOther
  23. 23

    RAL number on the roofEF024140

    A number

  24. 24

    Colour below the roofEF024141

    Choose one value

    NoneWhiteCreamBlackGreyAnthraciteOther
  25. 25

    RAL number below the roofEF024142

    A number

  26. 26

    Total lengthEF000369

    A number in mm

  27. 27

    Length above roofEF020009

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.