Duct thermostat EC011172

Published Stats, switches and controllers EG015840

Features 18

  1. 1

    Measuring range minimum value (no longer used)EF020271

    A number in °C

  2. 2

    Measuring range maximum value (no longer used)EF020272

    A number in °C

  3. 3

    Adjustable differentialEF024001

    Yes or no

    YesNo
  4. 4

    Differential valueEF022691

    A range, from and to, in K

  5. 5

    Number of switch steps (no longer used)EF024024

    A number

  6. 6

    Differential between switch stepsEF022690

    A range, from and to, in K

  7. 7

    Sensor/feeler typeEF006254

    Choose one value

    CapillaryBimetalBulb typeOther
  8. 8

    Length of capillaryEF020114

    A number in m

  9. 9

    Max. medium temperature (continuous)EF020023

    A number in °C

  10. 10

    Maximum contact voltageEF020286

    A number in V

  11. 11

    Maximum contact loadEF022541

    A number in A

  12. 12

    Contact lockEF021420

    Yes or no

    YesNo
  13. 13

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP05IP10IP12IP20IP21IP22IP23IP24IP25
  14. 14

    Explosion-proofEF004663

    Yes or no

    YesNo
  15. 15

    Insert lengthEF020279

    A number in mm

  16. 16

    HeightEF000040

    A number in mm

  17. 17

    WidthEF000008

    A number in mm

  18. 18

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.