EC011173
Published
Stats, switches and controllers EG015840
Features 15
- 1
(no longer used)EF020271
A number in °C
- 2
(no longer used)EF020272
A number in °C
- 3
Adjustable differentialEF024001
Yes or no
YesNo - 4
Differential valueEF022691
A range, from and to, in K
- 5
Sensor typeEF006254
Choose one value
CapillaryBimetalBulb typeOther - 6
Max. pipe diameterEF024025
A number in mm
- 7
Max. medium temperature (continuous)EF020023
A number in °C
- 8
Max. contact voltageEF020286
A number in V
- 9
Max. contact loadEF022541
A number in A
- 10
Contact lockEF021420
Yes or no
YesNo - 11
(no longer used)EF021858
A number
- 12
Explosion-proofEF004663
Yes or no
YesNo - 13
HeightEF000040
A number in mm
- 14
WidthEF000008
A number in mm
- 15
DepthEF000049
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.