Room clock thermostat EC011309

Features 37

  1. 1

    ModelEF000010

    Choose one value

    On/OffOpenThermBrand-dependentOther
  2. 2

    Type of power supplyEF001469

    Choose one value

    NoneBattery24 V (no longer used)230 V
  3. 3

    ConnectionEF000443

    Choose one value

    WirelessTwo-wire (no longer used)Three-wire (no longer used)3-/4-wire
  4. 4

    With receiverEF020643

    Yes or no

    YesNo
  5. 5

    Measuring range minimum value (no longer used)EF020271

    A number in °C

  6. 6

    Measuring range maximum value (no longer used)EF020272

    A number in °C

  7. 7

    External sensorEF023999

    Yes or no

    YesNo
  8. 8

    With thermal feedbackEF000531

    Yes or no

    YesNo
  9. 9

    Control characteristicEF020644

    Choose one value

    PPIPIDOther
  10. 10

    Suitable for heating (no longer used)EF021772

    Yes or no

    YesNo
  11. 11

    Number of heater outputsEF020681

    A number

  12. 12

    Cooling (no longer used)EF021773

    Yes or no

    YesNo
  13. 13

    Number of cooler outputsEF020682

    A number

  14. 14

    Differential valueEF022691

    A range, from and to, in K

  15. 15

    Adjustable differentialEF024001

    Yes or no

    YesNo
  16. 16

    Selector switch for heating and heating with hot waterEF020908

    Yes or no

    YesNo
  17. 17

    Sensor/feeler typeEF006254

    Choose one value

    BimetalResistance sensorOther
  18. 18

    Temperature readableEF021360

    Yes or no

    YesNo
  19. 19

    With displayEF000458

    Yes or no

    YesNo
  20. 20

    Type of clockEF005371

    Choose one value

    Day clockWeek clockYear clockOther
  21. 21

    Clock modelEF020684

    Choose one value

    DigitalAnalogue
  22. 22

    Overtime switchEF020909

    Yes or no

    YesNo
  23. 23

    OptimisationEF021362

    Yes or no

    YesNo
  24. 24

    With tap water circuitEF020680

    Yes or no

    YesNo
  25. 25

    OperationEF002147

    Choose one value

    TurnKey (no longer used)Touch screen
  26. 26

    Weather-dependent control systemEF020646

    Yes or no

    YesNo
  27. 27

    Number of switching programmesEF021363

    A number

  28. 28

    Contact type (no longer used)EF023906

    Choose one value

    Make (normally open) (no longer used)Break (normally closed) (no longer used)Change-over contact (no longer used)Electronic
  29. 29

    Max. contact voltageEF020286

    A number in V

  30. 30

    Max. contact loadEF022541

    A number in A

  31. 31

    Level of protection (IP value) (no longer used)EF021858

    A number

  32. 32

    Explosion-proofEF004663

    Yes or no

    YesNo
  33. 33

    ColourEF000007

    Choose one value

    Cream-white (no longer used)Clear white (no longer used)GreyBlackAnthraciteBeigeBlueBrownYellowGreen
  34. 34

    RAL-numberEF000116

    A number

  35. 35

    WidthEF000008

    A number in mm

  36. 36

    DepthEF000049

    A number in mm

  37. 37

    HeightEF000040

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.