Washbasin mixing tap EC011328

Features 63

  1. 1

    ModelEF000010

    Choose one value

    MechanicalElectronicHybrid
  2. 2

    Type of gripEF017041

    Choose one value

    Single-gripTwo-gripHandleless
  3. 3

    Type of electronic operating methodEF016912

    Choose one value

    SensorTouch control/push buttonOther
  4. 4

    Self-closingEF020103

    Yes or no

    YesNo
  5. 5

    Type of temperature controlEF006974

    Choose one value

    NoneFixed settingManually operatedThermostaticOther
  6. 6

    Material tapEF020791

    Choose one value

    BrassStainless steelOther
  7. 7

    Surface protectionEF000139

    Choose one value

    UntreatedChromium-platedNickel-platedCoatedGiltOther
  8. 8

    Surface treatmentEF025109

    Choose one value

    BrushedPolishedSandedOther
  9. 9

    Basic colourEF002671

    Choose one value

    AluminiumBlackBlueBrassBronzeChromeCopperGoldGreenGrey
  10. 10

    Accent colourEF023686

    Choose one value

    AluminiumBlackBlueBrassBronzeChromeCopperGoldGreenGrey
  11. 11

    MountingEF005084

    Choose one value

    WallTop/tap hole mountingFloorOther
  12. 12

    Number of tap holesEF021808

    Choose one value

    1-hole2-hole3-holeOther
  13. 13

    Centre distanceEF021835

    A number in mm

  14. 14

    Connection supplyEF002286

    Choose one value

    Pipe (no longer used)Hose (compression)Hose (gland nut)Internal threadExternal threadOther
  15. 15

    Connection size supplyEF020785

    Choose one value

    3/8 inch (10)1/2 inch (15)3/4 inch (20)8 mm10 mmM26 x 1.5Other
  16. 16

    Spout modelEF020795

    Choose one value

    Fixed, bottomFixed, topRotating, bottomRotating, topOther
  17. 17

    Type of spoutEF022750

    Choose one value

    CastPipeOther
  18. 18

    Tap nozzleEF023688

    Choose one value

    OpenAnti-splash jet nozzleFoam jet nozzleOther
  19. 19

    Extendible spout with aeratorEF020871

    Yes or no

    YesNo
  20. 20

    Extendible spout with hand showerEF020872

    Yes or no

    YesNo
  21. 21

    With side showerEF016945

    Yes or no

    YesNo
  22. 22

    With stop valve for external equipmentEF020801

    Yes or no

    YesNo
  23. 23

    Type of stop valve for external equipmentEF011781

    Choose one value

    MechanicalElectronic
  24. 24

    With couplersEF007955

    Yes or no

    YesNo
  25. 25

    With rosettes/cover plateEF020794

    Yes or no

    YesNo
  26. 26

    With waste fittingEF021707

    Yes or no

    YesNo
  27. 27

    Type of waste fittingEF016943

    Choose one value

    Pop-up valve with vertical leverPop-up waste (click-clack)Strainer waste valveStrainer tilt plug waste valveStrainer plug waste valveOther
  28. 28

    Chain eye includedEF020800

    Yes or no

    YesNo
  29. 29

    With chainEF022182

    Yes or no

    YesNo
  30. 30

    With drain plugEF013612

    Yes or no

    YesNo
  31. 31

    With temperature limitEF002149

    Yes or no

    YesNo
  32. 32

    Temperature limit retrofittableEF014578

    Yes or no

    YesNo
  33. 33

    Scald protectionEF021760

    Yes or no

    YesNo
  34. 34

    With pre-filterEF017097

    Yes or no

    YesNo
  35. 35

    Cold start functionEF015280

    Yes or no

    YesNo
  36. 36

    Backflow safeguard according to EN 1717EF011775

    Choose one value

    NoneAA, free air gapEAEBEDHAHCHDLBOther
  37. 37

    With spring-back resistance for max. hot water temperatureEF016714

    Yes or no

    YesNo
  38. 38

    Max. tap capacity (at 300 kPa)EF012753

    A number in l/min

  39. 39

    With override stop for flow limitationEF016712

    Yes or no

    YesNo
  40. 40

    Volume supply classEF022042

    Choose one value

    NoneZASBCD
  41. 41

    With spring-back resistance for max. flowEF016713

    Yes or no

    YesNo
  42. 42

    Total construction heightEF020796

    A number in mm

  43. 43

    Construction height, underside of tap nozzleEF020797

    A number in mm

  44. 44

    Spout overhang lengthEF020789

    A number in mm

  45. 45

    Sound class according to EN ISO 3822EF016731

    Choose one value

    Group I, <= 20 dB(A)Group II, <= 30 dB(A)None
  46. 46

    Low-pressure modelEF020792

    Yes or no

    YesNo
  47. 47

    Max. supply temperatureEF001707

    A number in °C

  48. 48

    Can be disconnected under water pressureEF020803

    Yes or no

    YesNo
  49. 49

    Type of power supplyEF001469

    Choose one value

    BatteryBattery/mainsMains power supplyTurbineOther
  50. 50

    With transformerEF000278

    Yes or no

    YesNo
  51. 51

    Connection voltageEF003625

    A number in V

  52. 52

    Reserve accumulatorEF000958

    Yes or no

    YesNo
  53. 53

    Degree of protection (IP)EF005474

    Choose one value

    IP44IP45IP54IP55IP59KIP69KOther
  54. 54

    Operating distanceEF004121

    A range, from and to, in mm

  55. 55

    Flushing time adjustableEF025098

    Yes or no

    YesNo
  56. 56

    Flushing timeEF025099

    A range, from and to, in s

  57. 57

    Automatic cycle flushingEF024921

    Yes or no

    YesNo
  58. 58

    Frequency of cycle flushingEF024922

    A range, from and to, in h

  59. 59

    ProgrammingEF025102

    Choose one value

    ManualRemote controlManually/remote controlOther
  60. 60

    With building management system connectionEF022133

    Yes or no

    YesNo
  61. 61

    Certified according to BelgaquaEFBE0001

    Yes or no

    YesNo
  62. 62

    KIWA certifiedEFNL0001

    Yes or no

    YesNo
  63. 63

    Type approval according to BBR/EKSEFSE0002

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.