Water tap EC011375

A valve used to control water flow from a pipe.

Features 32

  1. 1

    ModelEF000010

    Choose one value

    MechanicalElectronicHybrid
  2. 2

    With handleEF005050

    Yes or no

    YesNo
  3. 3

    Key operatedEF022256

    Yes or no

    YesNo
  4. 4

    Type of electronic operationEF016912

    Choose one value

    SensorTouch control/push buttonOther
  5. 5

    Self-closingEF020103

    Yes or no

    YesNo
  6. 6

    Tap materialEF020791

    Choose one value

    BrassStainless SteelOther
  7. 7

    Surface ProtectionEF000139

    Choose one value

    Chrome platedOther
  8. 8

    Mounting MethodEF000003

    Choose one value

    WallTop/tap holeTopBath edge / tile edgeOther
  9. 9

    With rosetteEF021480

    Yes or no

    YesNo
  10. 10

    With outletEF020788

    Yes or no

    YesNo
  11. 11

    Size of supply connectionEF020785

    Choose one value

    3/8 inch1/2 inch3/4 inch1 inchOther
  12. 12

    Outlet modelEF020795

    Choose one value

    FixedRotating, bottomRotating, top
  13. 13

    Outlet overhang lengthEF020789

    A number in mm

  14. 14

    Tap nozzleEF023688

    Choose one value

    OpenAnti-splash jet nozzleFoam jet nozzleWith hose connectionExternal threadOther
  15. 15

    With aeratorEF020972

    Yes or no

    YesNo
  16. 16

    Nominal diameter, outletEF022337

    Choose one value

    3/8 inch1/2 inch3/4 inch1 inchOther
  17. 17

    Max. supply temperatureEF001707

    A number in °C

  18. 18

    Backflow safeguard according to EN 1717EF011775

    Choose one value

    AAEBEDHAHCHDLBOther
  19. 19

    Maximum tap capacity (at 300 kPa)EF012753

    A number in l/min

  20. 20

    Volume supply classEF022042

    Choose one value

    NoneZASBCD
  21. 21

    Type of power supplyEF001469

    Choose one value

    BatteryBattery/mainsMains power supplyTurbineOther
  22. 22

    Sound class according to EN ISO 3822EF016731

    Choose one value

    Group I,<= 20 dB(A)Group II, <=30 dB(A)None
  23. 23

    With transformerEF000278

    Yes or no

    YesNo
  24. 24

    Connection VoltageEF003625

    A number in V

  25. 25

    Reserve accumulatorEF000958

    Yes or no

    YesNo
  26. 26

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP44IP45IP54IP55IP59KIP69KOther
  27. 27

    Operating distanceEF004121

    A range, from and to, in mm

  28. 28

    Flushing time adjustableEF025098

    Yes or no

    YesNo
  29. 29

    Flushing timeEF025099

    A range, from and to, in s

  30. 30

    ProgrammingEF025102

    Choose one value

    ManualRemote controlManually/remote controlOther
  31. 31

    With building management system connectionEF022133

    Yes or no

    YesNo
  32. 32

    ColourEF000007

    Choose one value

    BlackBrassChromeCopperGoldNickelPlatinumStainless SteelSteelWhiteOther

Codes after each name are ETIM feature codes. Use them, not the names, in product data.