Electrically controlled two-way control valve EC011408

An electrically controlled two-way control valve is a valve with two ports that regulates the flow of liquids or gases by means of an electric actuator. The actuator modulates or switches the valve position based on control signals, allowing precise automatic regulation in HVAC, water, or process systems.

Features 62

  1. 1

    Housing materialEF001596

    Choose one value

    AluminumBrassBronzeCast ironCopperPlasticStainless steelSteelOther
  2. 2

    Material qualityEF001257

    Choose one value

    Stainless steel 304 (1.4301)Stainless steel 304 L (1.4306)Stainless steel 316 (1.4401)Stainless steel 316 L (1.4404)Stainless steel 316 (1.4408)Stainless steel 316 (1.4409)Stainless steel 316 Ti (1.4571)Stainless steel 321 (1.4541)Cast steelForged steel
  3. 3

    Nominal diameterEF023191

    Choose one value

    1/8 inch (6)DN 61/4 inch (8)DN 83/8 inch (10)DN 101/2 inch (15)DN 153/4 inch (20)DN 20
  4. 4

    Outer pipe diameter all connectionsEF020126

    A number in mm

  5. 5

    ConnectionsEF022472

    Choose one value

    Internal thread cylindrical BSPP-G (ISO 228-1)Internal thread metricInternal thread conical (NPT)Internal thread conical BSPT-Rc (ISO 7-1 / EN 10226-1)Internal thread cylindrical BSPT-Rp (ISO 7-1 / EN 10226-1)External thread conical BSPT-R (ISO 7-1 / EN 10226-1)External thread cylindrical BSPP-G (ISO 228-1)External thread metricExternal thread conical (NPT)Flange
  6. 6

    With coupling connection 1EF021872

    Yes or no

    YesNo
  7. 7

    With coupling connection 2EF021873

    Yes or no

    YesNo
  8. 8

    Device pressure classEF020007

    Choose one value

    PressurelessPN 2.5PN 3.2PN 4PN 6PN 8PN 10PN 12.5PN 16PN 20
  9. 9

    Flange compression classEF020149

    Choose one value

    PN 2.5PN 6PN 10PN 16PN 25PN 40PN 63PN 100PN 160PN 250
  10. 10

    Max. pressure difference in opened positionEF024113

    A number in bar

  11. 11

    Medium temperature (continuous)EF023182

    A range, from and to, in °C

  12. 12

    Surface protectionEF000139

    Choose one value

    UntreatedCoatedNickel-platedPrimerChromium-platedOther
  13. 13

    Kvs valueEF022466

    A number in m³/h

  14. 14

    Leakage loss of Kvs valueEF024114

    A number in %

  15. 15

    Characteristic curveEF024116

    Choose one value

    LinearEqual percentageQuadratic
  16. 16

    Control ratio (Svo)EF024115

    A number in %

  17. 17

    Closing pressureEF024117

    A number in bar

  18. 18

    Voltage ratingEF004127

    A range, from and to, in V

  19. 19

    Voltage typeEF000187

    Choose one value

    ACDCAC/DC
  20. 20

    FrequencyEF005455

    Choose one value

    50 Hz60 Hz50/60 HzOther
  21. 21

    Control signalEF000513

    Choose one value

    2-point3-point0 - 10 V2-10 V0 - 20 V0 - 20 mA4 - 20 mARS-485RS-232LON-Works
  22. 22

    Zero-pressure return flowEF021861

    Choose one value

    NoneDeactivated when openDeactivated when closed
  23. 23

    Position reporting systemEF021862

    Choose one value

    None0 - 10 V0 - 5 V0 - 20 mAPotentiometerBus connection
  24. 24

    Adjustable position feedback signalEF024205

    Yes or no

    YesNo
  25. 25

    TransmissionEF023898

    Choose one value

    With cogwheelsMagneticHydraulicThermal
  26. 26

    Adjustable operating rangeEF023901

    Yes or no

    YesNo
  27. 27

    Auxiliary contactsEF024109

    Yes or no

    YesNo
  28. 28

    With end contactsEF022697

    Yes or no

    YesNo
  29. 29

    Suitable for manual operationEF002978

    Yes or no

    YesNo
  30. 30

    Operating timeEF021863

    A number in s

  31. 31

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP05IP10IP12IP20IP21IP22IP23IP24IP25
  32. 32

    Explosion-proofEF004663

    Yes or no

    YesNo
  33. 33

    Max. electric power inputEF023037

    A number in VA

  34. 34

    Allowable relative humidityEF023900

    A range, from and to, in %

  35. 35

    Ambient temperatureEF002386

    A range, from and to, in °C

  36. 36

    Length of connection 1EF020151

    A number in mm

  37. 37

    Working length connection 1EF020153

    A number in mm

  38. 38

    Length of connection 2EF020152

    A number in mm

  39. 39

    Working length connection 2EF020154

    A number in mm

  40. 40

    HeightEF000040

    A number in mm

  41. 41

    WidthEF000008

    A number in mm

  42. 42

    DepthEF000049

    A number in mm

  43. 43

    Wi-FiEF008851

    Yes or no

    YesNo
  44. 44

    BluetoothEF007699

    Yes or no

    YesNo
  45. 45

    Communication medium wiredEF018326

    Yes or no

    YesNo
  46. 46

    Connector (information technology)EF008427

    Choose one value

    RJ45OtherRJ12
  47. 47

    RS-232 protocol supportEF007312

    Yes or no

    YesNo
  48. 48

    RS-485 protocol supportEF007314

    Yes or no

    YesNo
  49. 49

    EF027336

    Yes or no

    YesNo
  50. 50

    Bus system KNX-RF (Radio Frequency)EF008855

    Yes or no

    YesNo
  51. 51

    Supporting protocol for MatterEF018256

    Yes or no

    YesNo
  52. 52

    Supporting protocol for Modbus TCPEF016392

    Yes or no

    YesNo
  53. 53

    Supporting protocol for MQTTEF017165

    Yes or no

    YesNo
  54. 54

    EF027271

    Yes or no

    YesNo
  55. 55

    Supporting protocol for Z-WaveEF014564

    Yes or no

    YesNo
  56. 56

    Supporting protocol for ZigBeeEF014568

    Yes or no

    YesNo
  57. 57

    Compatible with Google AssistantEF014926

    Yes or no

    YesNo
  58. 58

    EF027338

    Yes or no

    YesNo
  59. 59

    EF027339

    Yes or no

    YesNo
  60. 60

    EF027355

    Yes or no

    YesNo
  61. 61

    EF027342

    Yes or no

    YesNo
  62. 62

    EF027343

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.