Heat pump (water/water) EC011794

Features 58

  1. 1

    Suitable for open well (groundwater)EF025846

    Yes or no

    YesNo
  2. 2

    Suitable for closed circuit well (soil collector)EF025847

    Yes or no

    YesNo
  3. 3

    Heating capacity at 0/35 °C (B0/W35) according to EN 14511EF013957

    A range, from and to, in kW

  4. 4

    COP at 0/35 °C (B0/W35) according to EN 14511EF025879

    A number

  5. 5

    Heating capacity at 10/35 °C (W10/W35) according to EN 14511EF013958

    A range, from and to, in kW

  6. 6

    COP at 10/35 °C (W10/W35) according to EN 14511EF012662

    A number

  7. 7

    COPd at Tj = +7 °CEF010933

    A number

  8. 8

    Water volume of central heating waterEF016685

    A number in l

  9. 9

    Suitable for hot tap waterEF021195

    Yes or no

    YesNo
  10. 10

    Hot tap water feature integratedEF025849

    Yes or no

    YesNo
  11. 11

    Type of hot tap water featureEF016633

    Choose one value

    Coil/batteryPlate heat exchangerTank-in-tank (double walled)Other
  12. 12

    Material hot tap water featureEF016634

    Choose one value

    CopperCopper sheathed steelStainless steelOther
  13. 13

    Water volume of hot tap waterEF021121

    A number in l

  14. 14

    For refrigeration installationsEF024798

    Yes or no

    YesNo
  15. 15

    Cooling integratedEF025848

    Yes or no

    YesNo
  16. 16

    Cooling performance at 10/18 °C (W10/W18)EF017407

    A range, from and to, in kW

  17. 17

    Cooling performance at 15/18 °C (B15/W18)EF017406

    A range, from and to, in kW

  18. 18

    Suitable for swimming pool water heatingEF023919

    Yes or no

    YesNo
  19. 19

    Swimming pool controlsEF020666

    Yes or no

    YesNo
  20. 20

    With electric heating elementEF024815

    Yes or no

    YesNo
  21. 21

    Power electric heating elementEF025850

    A range, from and to, in kW

  22. 22

    Type of refrigerantEF024945

    Choose one value

    R32R134aR290R407cR410aR454cR744Other
  23. 23

    Refrigerant contentEF013833

    A number in kg

  24. 24

    Global warming potential (GWP)EF016979

    A number

  25. 25

    Connection voltageEF003625

    A number in V

  26. 26

    Fuse (slow) (no longer used)EF024947

    A number in A

  27. 27

    WidthEF000008

    A number in mm

  28. 28

    HeightEF000040

    A number in mm

  29. 29

    DepthEF000049

    A number in mm

  30. 30

    WeightEF000167

    A number in kg

  31. 31

    Sound performance level (according to EN12102 at 0/35 °C)EF025880

    A number in dB(A)

  32. 32

    Sound performance level according to EN 12102 at 10/35 °CEF017251

    A number in dB(A)

  33. 33

    Max. operating temperature sourceEF025881

    A range, from and to, in °C

  34. 34

    Max. heating water supply temperatureEF006333

    A number in °C

  35. 35

    Max. pressure of hot tap waterEF021120

    A number in bar

  36. 36

    Nominal volume flow rate source systemEF025883

    A number in l/s

  37. 37

    Maximum operating pressure source systemEF025882

    A number in bar

  38. 38

    Nominal volume flow rate output systemEF025884

    A number in l/s

  39. 39

    Max. operating pressure output systemEF025885

    A number in bar

  40. 40

    Outer pipe diameter tap water (no longer used)EF021084

    A number in mm

  41. 41

    Outer pipe diameter connection source systemEF025886

    A number in mm

  42. 42

    Outer pipe diameter connection output systemEF025887

    A number in mm

  43. 43

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP22IP24IP25IP2XIP30IP31
  44. 44

    CascadingEF000507

    Yes or no

    YesNo
  45. 45

    Remote operation possibleEF003361

    Yes or no

    YesNo
  46. 46

    Data transfer via USBEF008435

    Yes or no

    YesNo
  47. 47

    Data transfer via internetEF026126

    Yes or no

    YesNo
  48. 48

    Data transfer via bus connectionEF009428

    Yes or no

    YesNo
  49. 49

    SEER low temperature application (35 °C) at average conditions (no longer used)EF010784

    A number

  50. 50

    SEER low temperature application (35 °C) at colder conditions (no longer used)EF010785

    A number

  51. 51

    SEER low temperature application (35 °C) at warmer conditions (no longer used)EF010786

    A number

  52. 52

    SEER middle temperature application (55 °C) at average conditions (no longer used)EF010787

    A number

  53. 53

    SEER middle temperature application (55 °C) at colder conditions (no longer used)EF010788

    A number

  54. 54

    Seasonal space heating energy efficiency class according to 811/2013/EUEF016994

    Choose one value

    A+++A++A+ABCDEFG
  55. 55

    SEER middle temperature application (55 °C) at warmer conditions (no longer used)EF010789

    A number

  56. 56

    Water heating energy efficiency (Nwh)EF010599

    A number in %

  57. 57

    Water heating energy efficiency class according to 811/2013/EUEF016995

    Choose one value

    A+++A++A+ABCDEFG
  58. 58

    Capacity profileEF010777

    Choose one value

    XXXSXXSXSSMLXLXXL