Luminaire bollard EC000301
Features 48
- 1
Type of luminaireEF004259
Choose one value
Ground stakePedestal luminaireBollard luminaireSteleOther - 2
With base plateEF000093
Yes or no
YesNo - 3
With light sensorEF001203
Yes or no
YesNo - 4
With movement sensorEF000197
Yes or no
YesNo - 5
Lamp typeEF002423
Choose one value
Incandescent lampMetal halide lampHV halogen lampHigh pressure sodium-vapour lampLow pressure sodium-vapour lampLV halogen lampInduction lampCompact fluorescent lampLED exchangeableLED not exchangeable - 6
With light sourceEF005905
Yes or no
YesNo - 7
Suitable for number of light sourcesEF006436
A number
- 8
Lamp holderEF000048
Choose one value
2G72G102G112G132GX13B15dB22dBA9sE10E14 - 9
Housing materialEF001596
Choose one value
AluminiumCast ironSteelStainless steelCopperPlasticStoneOther - 10
Surface protectionEF000139
Choose one value
LacqueredPlastic-coatedPowder coatingGalvanisedOtherUntreated - 11
Housing colourEF000136
Choose one value
AluminiumAnthraciteBeigeBlueBrownBronzeChromeStainless steelYellowGold - 12
Cover materialEF004284
Choose one value
Glass, opalGlass, structuredGlass, transparentGlass, matt/satinizedPlastic, opalPlastic, structuredPlastic, transparentPlastic, matt/satinizedOtherWithout cover - 13
Voltage typeEF000187
Choose one value
ACDCAC/DC - 14
Nominal voltageEF005127
A range, from and to, in V
- 15
LED nominal current at constant current (no longer used)EF012150
A range, from and to, in mA
- 16
Type of control gearEF000381
Choose one value
Electronic transformerElectronic ballastLow-loss ballast inductiveLow-loss ballast compensatedLED operating device voltage-controlledLED operating device current-controlledMagnetic transformerNot required - 17
With control gearEF007556
Yes or no
YesNo - 18
Light distributorEF012170
Choose one value
Diffuser lens/optic/panelFocal lensReflectorRefractor lensOtherNone - 19
Energy efficiency class of the built-in lampEF012487
Choose one value
A++, A+, A (LED)Other - 20
Energy efficiency class of the provided exchangeable built-in lampEF012488
Choose one value
A++A+ABCDE - 21
Highest energy efficiency class of the exchangeable lampEF012489
Choose one value
A++A+ABCDE - 22
Lowest energy efficiency class of the exchangeable lampEF012490
Choose one value
A++A+ABCDE - 23
Power supply energy efficiency index (EEI) (no longer used)EF011875
Choose one value
A1 BATA1A2 BATA2A3B1B2COther - 24
Rated lifetime L70/B10 at 25 °C (no longer used)EF011869
A number in h
- 25
Rated lifetime L70/B50 at 25 °CEF011870
A number in h
- 26
Rated life time L80/B10 at 25 °C (no longer used)EF011871
A number in h
- 27
Rated lifetime L80/B50 at 25 °C (no longer used)EF011872
A number in h
- 28
Rated lifetime L90/B10 at 25 °C (no longer used)EF011873
A number in h
- 29
Rated lifetime L90/B50 at 25 °C (no longer used)EF011874
A number in h
- 30
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 31
Degree of protection (NEMA)EF011959
Choose one value
1233R44X1213OtherNot applicable (no longer used) - 32
Impact strengthEF004293
Choose one value
IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09IK10 - 33
Protection class according to IEC 61140EF000004
Choose one value
IIIIIINone - 34
Suitable for lamp powerEF000280
A range, from and to, in W
- 35
Max. system powerEF009347
A number in W
- 36
Rated luminous flux according to IEC 62722-2-1 (no longer used)EF009349
A number in lm
- 37
Colour of lightEF009350
Choose one value
BlueRedAmberGreenYellowRGBRGBWWhiteMulti-colouredOther - 38
Colour temperatureEF009346
A range, from and to, in K
- 39
Colour rendering index CRIEF000442
Choose one value
20-3940-5960-6970-7980-8990-100 - 40
Power factorEF025740
A number
- 41
WidthEF000008
A number in mm
- 42
Height/depthEF001456
A number in mm
- 43
LengthEF001438
A number in mm
- 44
DiameterEF000551
A number in mm
- 45
Type of wiringEF011868
Choose one value
Suitable for loop-through wiringLoop-through wiring includedEnding - 46
Number of polesEF001391
A number
- 47
Conductor cross sectionEF000085
A number in mm²
- 48
Connection typeEF000124
Choose one value
CrimpingBlade terminalSolderInsulation displacement connectorScrewed terminalPush-in clampPinching contact (no longer used)Other
Codes after each name are ETIM feature codes. Use them, not the names, in product data.