Explosion proof emergency and security luminaire EC000981
Features 50
- 1
Mounting MethodEF000003
Choose one value
Surface mountingBuilt-inSurface mounting/recessed mountingLine lighting systemMounting rail - 2
Power supply system (no longer used)EF000233
Choose one value
CentralPeripheral - 3
Light source typeEF002423
Choose one value
Incandescent lampCompact fluorescent lampFluorescent lampLED replaceableLED non-replaceableOther - 4
Light source includedEF005905
Yes or no
YesNo - 5
Number of lampsEF006436
A number
- 6
Housing MaterialEF001596
Choose one value
AluminiumSteelStainless SteelPlasticOther - 7
Voltage typeEF000187
Choose one value
ACDCAC/DC - 8
Nominal voltageEF005127
A range, from and to, in V
- 9
Control gearEF000381
Choose one value
Electronic transformerElectronic ballastConventional ballast/low-loss ballast inductiveConventional ballast/low-loss ballast compensatedLED driver constant voltageLED driver constant currentMagnetic transformerNot required - 10
Replaceable control gearEF016286
Yes or no
YesNo - 11
Labelling typeEF001277
Choose one value
StickerInsert sheet/plateAcrylic plateOtherNone - 12
Type of indicatorEF001278
Choose one value
Single/double-sidedSingle-sided - 13
Viewing distanceEF008732
A number in m
- 14
Monitoring equipment (no longer used)EF008091
Choose one value
Test buttonAutomatic self testSafety module for monitoring (central feeded system)OtherNone - 15
Wiring systemEF002960
Choose one value
Standby switchingContinuous circuit/emergency circuit - 16
Energy efficiency class of integrated lampEF012487
Choose one value
A++, A+, A (LED)Other - 17
Energy efficiency class of the replaceable lamp suppliedEF012488
Choose one value
A++A+ABCDE - 18
Highest energy efficiency class of replaceable lampEF012489
Choose one value
A++A+ABCDE - 19
Lowest energy efficiency class of replaceable lampEF012490
Choose one value
A++A+ABCDE - 20
Rated life time L70/B50 at 25 °CEF011870
A number in h
- 21
Rated life time L90/B10 at 25 °C (no longer used)EF011873
A number in h
- 22
Lumen maintenance at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015687
A number in %
- 23
Failure rate at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015691
A number in %
- 24
Degree of Protection (IP rating)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 25
Impact Resistance (IK Rating)EF004293
Choose one value
IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09IK10 - 26
Protection class according to IEC 61140EF000004
Choose one value
IIIIIINone - 27
For ATEX classification, Ex-zone gasEF005728
Choose one value
0, 1, 21, 22None - 28
For ATEX classification, Ex-zone dustEF008404
Choose one value
20, 21, 2221, 2222None - 29
Nominal operation timeEF012518
A range, from and to, in h
- 30
Lamp powerEF000280
A range, from and to, in W
- 31
Maximum system powerEF009347
A number in W
- 32
Rated luminous flux acc. IEC 62722-2-1 (no longer used)EF009349
A number in lm
- 33
Luminous flux in emergency operationEF008731
A number in lm
- 34
Colour of lightEF009350
Choose one value
BlueRedAmberGreenYellowRGBRGBWWhiteMulti colourOther - 35
Colour temperatureEF009346
A range, from and to, in K
- 36
Colour rendering index (CRI/Ra)EF000442
Choose one value
20-3940-5960-6970-7980-8990-100 - 37
Power factorEF025740
A number
- 38
Constant luminous flux controlEF009482
Yes or no
YesNo - 39
WidthEF000008
A number in mm
- 40
Height/depthEF001456
A number in mm
- 41
LengthEF001438
A number in mm
- 42
Outer diameterEF000015
A number in mm
- 43
Recess widthEF000846
A number in mm
- 44
Recess height/depthEF023518
A number in mm
- 45
Recess lengthEF004265
A number in mm
- 46
Recess diameterEF000943
A number in mm
- 47
Type of cablingEF011868
Choose one value
Suitable for through wiringThrough wiring includedEnding - 48
Number of PolesEF001391
A number
- 49
Conductor cross sectionEF000085
A number in mm²
- 50
Connection TypeEF000124
Choose one value
CrimpingBlade terminalSolderInsulation Displacement ConnectorScrewed TerminalScrewless TerminalOther
Codes after each name are ETIM feature codes. Use them, not the names, in product data.