Explosion proof emergency and security luminaire EC000981

Explosion-proof lamp for visual highlighting of safety notices and escape routes.

Features 50

  1. 1

    Mounting MethodEF000003

    Choose one value

    Built-inLine lighting systemMounting railSurface mountingSurface mounting/recessed mountingOther
  2. 2

    Emergency power supply systemEF018918

    Choose one value

    Central (central battery)Central (central battery) and peripheral (individual battery)Peripheral (individual battery)Suitable for peripheral (individual battery) with an accessory kitNone
  3. 3

    Light source typeEF002423

    Choose one value

    Compact fluorescent lampFluorescent lampIncandescent lampLED replaceableLED non-replaceableOther
  4. 4

    Light source includedEF005905

    Yes or no

    YesNo
  5. 5

    Number of lampsEF006436

    A number

  6. 6

    Housing MaterialEF001596

    Choose one value

    AluminiumPlasticStainless SteelSteelOther
  7. 7

    Voltage typeEF000187

    Choose one value

    ACDCAC/DC
  8. 8

    Nominal voltageEF005127

    A range, from and to, in V

  9. 9

    Control gearEF000381

    Choose one value

    Electronic ballastElectronic transformerLED driver constant currentLED driver constant voltageConventional ballast/low-loss ballast compensatedConventional ballast/low-loss ballast inductiveMagnetic transformerNot required
  10. 10

    Replaceable control gearEF016286

    Yes or no

    YesNo
  11. 11

    Labelling typeEF001277

    Choose one value

    Acrylic plateInsert sheet/plateStickerOtherNone
  12. 12

    Type of indicatorEF001278

    Choose one value

    Single/double-sidedSingle-sided
  13. 13

    Viewing distanceEF008732

    A number in m

  14. 14

    Emergency function monitoring systemEF018921

    Choose one value

    Automatic self testSafety module for monitoring (central feeded system)Test buttonOtherNone
  15. 15

    Wiring systemEF002960

    Choose one value

    Continuous circuit/emergency circuitStandby switching
  16. 16

    Energy efficiency class of light source according to EU regulation 2019/2015EF016835

    Choose one value

    ABCDEFGNot required
  17. 17

    Rated life time L70/B50 at 25 °CEF011870

    A number in h

  18. 18

    Lumen maintenance at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015687

    A number in %

  19. 19

    Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)EF015689

    A number in %

  20. 20

    Failure rate at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015691

    A number in %

  21. 21

    Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)EF015693

    A number in %

  22. 22

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  23. 23

    Impact Resistance (IK Rating)EF004293

    Choose one value

    IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09
  24. 24

    Protection class according to IEC 61140EF000004

    Choose one value

    IIIIIINone
  25. 25

    For ATEX classification, Ex-zone gasEF005728

    Choose one value

    0, 1, 21, 22None
  26. 26

    For ATEX classification, Ex-zone dustEF008404

    Choose one value

    20, 21, 2221, 2222None
  27. 27

    Nominal operation timeEF012518

    A range, from and to, in h

  28. 28

    Lamp powerEF000280

    A range, from and to, in W

  29. 29

    Maximum system powerEF009347

    A number in W

  30. 30

    Rated luminous flux according to IEC 62722-2- 1EF018714

    A range, from and to, in lm

  31. 31

    Luminous flux in emergency operationEF008731

    A number in lm

  32. 32

    Colour of lightEF009350

    Choose one value

    AmberBlueGreenMulti colourRedRGBRGBWWhiteYellowOther
  33. 33

    Colour temperatureEF009346

    A range, from and to, in K

  34. 34

    Colour rendering index (CRI/Ra)EF000442

    Choose one value

    20-3940-5960-6970-7980-8990-100
  35. 35

    Ambient temperatureEF002386

    A range, from and to, in °C

  36. 36

    Power factorEF025740

    A number

  37. 37

    Constant luminous flux controlEF009482

    Yes or no

    YesNo
  38. 38

    WidthEF000008

    A number in mm

  39. 39

    Height/depthEF001456

    A number in mm

  40. 40

    LengthEF001438

    A number in mm

  41. 41

    Outer diameterEF000015

    A number in mm

  42. 42

    Recess widthEF000846

    A number in mm

  43. 43

    Recess height/depthEF023518

    A number in mm

  44. 44

    Recess lengthEF004265

    A number in mm

  45. 45

    Recess diameterEF000943

    A number in mm

  46. 46

    Type of cablingEF011868

    Choose one value

    EndingThrough wiring includedSuitable for through wiring
  47. 47

    Number of PolesEF001391

    A number

  48. 48

    Conductor cross sectionEF000085

    A number in mm²

  49. 49

    Connection TypeEF000124

    Choose one value

    BusBusbar adapterCableConnecting cord with plugInsulation Displacement ConnectorPlugScrewless TerminalScrewed TerminalOther
  50. 50

    Connectable conductor cross sectionEF008200

    A range, from and to, in mm²

Codes after each name are ETIM feature codes. Use them, not the names, in product data.