Voltage monitoring relay EC001438

Published Relays EG000019

Features 29

  1. 1

    Type of electrical connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPrinted circuit board (PCB) connectionInsulation displacement connectionScrew connectionWelding connectionPlug-in connection
  2. 2

    With detachable clampsEF003340

    Yes or no

    YesNo
  3. 3

    Single-phase under voltage availableEF003390

    Yes or no

    YesNo
  4. 4

    Three-phase under voltage availableEF003391

    Yes or no

    YesNo
  5. 5

    Single-phase overvoltage availableEF003392

    Yes or no

    YesNo
  6. 6

    Three-phase overvoltage availableEF003393

    Yes or no

    YesNo
  7. 7

    Single-phase hysteresis (window function) availableEF003394

    Yes or no

    YesNo
  8. 8

    Three-phase hysteresis (window function) availableEF003395

    Yes or no

    YesNo
  9. 9

    Contains DC undervoltage monitoringEF003396

    Yes or no

    YesNo
  10. 10

    Contains DC overvoltage functionEF003397

    Yes or no

    YesNo
  11. 11

    Contains DC voltage hysteresis (window function) monitoringEF003398

    Yes or no

    YesNo
  12. 12

    Voltage measuring range 1EF006134

    A range, from and to, in V

  13. 13

    Voltage measuring range 2EF006135

    A range, from and to, in V

  14. 14

    Type of voltage measuring rangeEF003399

    Choose one value

    ACDCAC/DC
  15. 15

    Rated control supply voltage at AC 50HZEF003978

    A range, from and to, in V

  16. 16

    Rated control supply voltage at AC 60HZEF003979

    A range, from and to, in V

  17. 17

    Rated control supply voltage at DCEF003980

    A range, from and to, in V

  18. 18

    Actuating voltage typeEF008242

    Choose one value

    ACDCAC/DC
  19. 19

    Response value voltageEF008193

    A range, from and to, in V

  20. 20

    Minimum adjustable start delay when power is appliedEF008190

    A number in s

  21. 21

    Maximum adjustable start delay when power is appliedEF008189

    A number in s

  22. 22

    Minimum adjustable off-delay timeEF008192

    A number in s

  23. 23

    Maximum adjustable off-delay timeEF008191

    A number in s

  24. 24

    Number of contacts as normally closed (NC)EF008255

    A number

  25. 25

    Number of contacts as normally open (NO)EF008256

    A number

  26. 26

    Number of change-over contactsEF008257

    A number

  27. 27

    WidthEF000008

    A number in mm

  28. 28

    HeightEF000040

    A number in mm

  29. 29

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.