Voltage monitoring relay EC001438

A relay that monitors voltage levels and triggers alarms or actions.

Published Relays EG000019

Features 36

  1. 1

    Type of electrical connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPrinted circuit board (PCB) connectionInsulation displacement connectionScrew connectionWelding connectionPlug-in connection
  2. 2

    Tightening momentEF005520

    A range, from and to, in Nm

  3. 3

    With detachable clampsEF003340

    Yes or no

    YesNo
  4. 4

    External power supply requiredEF003292

    Yes or no

    YesNo
  5. 5

    Supply voltage typeEF002991

    Choose one value

    ACDCAC/DC
  6. 6

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  7. 7

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  8. 8

    Supply voltage DCEF007534

    A range, from and to, in V

  9. 9

    Voltage measuring range 1EF006134

    A range, from and to, in V

  10. 10

    Voltage measuring range 2EF006135

    A range, from and to, in V

  11. 11

    Type of voltage measuring rangeEF003399

    Choose one value

    ACDCAC/DC
  12. 12

    Response value voltageEF008193

    A range, from and to, in V

  13. 13

    Single-phase under voltage availableEF003390

    Yes or no

    YesNo
  14. 14

    Three-phase under voltage availableEF003391

    Yes or no

    YesNo
  15. 15

    Single-phase overvoltage availableEF003392

    Yes or no

    YesNo
  16. 16

    Three-phase overvoltage availableEF003393

    Yes or no

    YesNo
  17. 17

    Single-phase hysteresis (window function) availableEF003394

    Yes or no

    YesNo
  18. 18

    Three-phase hysteresis (window function) availableEF003395

    Yes or no

    YesNo
  19. 19

    Contains DC undervoltage monitoringEF003396

    Yes or no

    YesNo
  20. 20

    Contains DC overvoltage functionEF003397

    Yes or no

    YesNo
  21. 21

    Contains DC voltage hysteresis (window function) monitoringEF003398

    Yes or no

    YesNo
  22. 22

    Minimum adjustable start delay when power is appliedEF008190

    A number in s

  23. 23

    Maximum adjustable start delay when power is appliedEF008189

    A number in s

  24. 24

    Minimum adjustable off-delay timeEF008192

    A number in s

  25. 25

    Maximum adjustable off-delay timeEF008191

    A number in s

  26. 26

    Number of contacts as normally closed (NC)EF008255

    A number

  27. 27

    Number of contacts as normally open (NO)EF008256

    A number

  28. 28

    Number of change-over contactsEF008257

    A number

  29. 29

    Voltage type (operating voltage)EF005294

    Choose one value

    ACDCAC/DC
  30. 30

    Operating voltage at AC 50 HzEF008206

    A range, from and to, in V

  31. 31

    Operating voltage at AC 60 HzEF008207

    A range, from and to, in V

  32. 32

    Operating voltage at DCEF008208

    A range, from and to, in V

  33. 33

    Rated switch currentEF006706

    A number in A

  34. 34

    WidthEF000008

    A number in mm

  35. 35

    HeightEF000040

    A number in mm

  36. 36

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.