Box/housing for built-in mounting in the wall/ceiling EC002601
Features 36
- 1
Mounting MethodEF000003
Choose one value
Concrete buildingHollow WallFlush mountedFacing brickworkHollow ceilingOther - 2
ShapeEF000051
Choose one value
RoundOvalSquareRectangularOther - 3
Construction typeEF000767
Choose one value
Flush mounted boxDevice connection box (round/square)Cable junction boxCentral conduit boxOther - 4
ModelEF000010
Choose one value
SingleOne and a halfDoubleCEE (no longer used)PerilexOther - 5
Equipped withEF000557
Choose one value
ClampSupport railMounting platePotential equalizationOtherNone - 6
DiameterEF000551
A number in mm
- 7
LengthEF001438
A number in mm
- 8
WidthEF000008
A number in mm
- 9
DepthEF000049
A number in mm
- 10
Internal depthEF001131
A number in mm
- 11
For number of electric fittingsEF004702
A number
- 12
Device mounting methodEF004508
Choose one value
ScrewingSpreadScrew or spread out - 13
With screwsEF005066
Yes or no
YesNo - 14
Type of housing feed-throughEF007661
Choose one value
PreembossingSeal membranePipe socketTrimmable step membraneOtherNone - 15
For conduit/tube diameterEF005496
Choose one value
16 mm19 mm16/19 mm20 mm20/25 mm25 mm32 mmOther - 16
Suitable for cable outer diameterEF005466
A range, from and to, in mm
- 17
Pipe lockingEF005657
Yes or no
YesNo - 18
Entry point on rearEF005604
Yes or no
YesNo - 19
Number of entry pointsEF003593
A number
- 20
MaterialEF002169
Choose one value
PlasticSteelOther - 21
Halogen FreeEF000025
Yes or no
YesNo - 22
Surface ProtectionEF000139
Choose one value
Pre-galvanisedGalvanic/electrolytic zinc platedOtherUntreated - 23
ColourEF000007
Choose one value
BlueYellowGreyGreenOrangeRedBlackWhiteOther - 24
Degree of Protection (IP rating)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 25
Cover (no longer used)EF007726
Choose one value
Transparent (no longer used)Not transparent (no longer used)Mineral fibres plateNone - 26
Cover attachmentEF004586
Choose one value
Snap onBayonet latchScrewedHingedCentre mountingNot applicable (no longer used) - 27
SealableEF001454
Yes or no
YesNo - 28
Circuit integrityEF001613
Choose one value
E 30E 60E 90None - 29
With screeningEF005032
Yes or no
YesNo - 30
Airtight (no longer used)EF005430
Yes or no
YesNo - 31
Max. conductor cross sectionEF004969
A number in mm²
- 32
Number of poles of the clampEF008016
A number
- 33
Clamp position fixedEF007889
Yes or no
YesNo - 34
Luminaire hook mountingEF004902
Yes or no
YesNo - 35
NozzleEF008076
Choose one value
Tunnel branch pipeSquare branch pipeDouble nozzlePipe socketOtherNone - 36
With fixing lugsEF005060
Yes or no
YesNo
Codes after each name are ETIM feature codes. Use them, not the names, in product data.