Flush mounted box/housing EC002601
An enclosure designed for flush mounting within walls or ceilings.
Features 52
- 1
Mounting MethodEF000003
Choose one value
Concrete buildingConcrete building/hollow wallFacing brickworkFlush mountedHollow ceilingHollow WallOther - 2
ShapeEF000051
Choose one value
RoundOvalSquareRectangularOctagonalOther - 3
Construction typeEF000767
Choose one value
Flush mounted boxDevice connection box (round/square)Cable junction boxCentral conduit boxOther - 4
ModelEF000010
Choose one value
SingleOne and a halfDouble3-fold4-foldCEE for industrial purposes (IEC 60309)PerilexOther - 5
Provided with revolving ringEF009204
Yes or no
YesNo - 6
CouplableEF001229
Yes or no
YesNo - 7
Equipped withEF000557
Choose one value
ClampSupport railMounting platePotential equalizationOtherNone - 8
DiameterEF000551
A number in mm
- 9
LengthEF001438
A number in mm
- 10
WidthEF000008
A number in mm
- 11
DepthEF005457
A range, from and to, in mm
- 12
Internal depthEF001131
A number in mm
- 13
Suitable for wall/board thicknessEF015116
A range, from and to, in mm
- 14
Number of units horizontalEF008858
A number
- 15
Number of units verticalEF008859
A number
- 16
For number of electric fittingsEF004702
A number
- 17
Device mounting methodEF004508
Choose one value
ScrewingSpreadScrew or spread out - 18
With screwsEF005066
Yes or no
YesNo - 19
Number of non-adjustable device fixing lugsEF017002
A number
- 20
Number of adjustable device fixing lugsEF017003
A number
- 21
Housing feed-through by break-out openingEF009763
Yes or no
YesNo - 22
Housing feed-through by seal membraneEF009206
Yes or no
YesNo - 23
Housing feed-through by nozzleEF009207
Yes or no
YesNo - 24
Housing feed-through by step membraneEF009208
Yes or no
YesNo - 25
For conduit/tube diameterEF005496
Choose one value
16 mm16/19 mm16/19/20 mm16/20 mm16/20/25 mm16/20/25/32 mm18/20/25 mm19 mm20 mm20/25 mm - 26
Suitable for cable outer diameterEF005466
A range, from and to, in mm
- 27
Pipe lockingEF005657
Yes or no
YesNo - 28
Pipe locking optionalEF009209
Yes or no
YesNo - 29
Entry point on rearEF005604
Yes or no
YesNo - 30
Number of entry pointsEF003593
A number
- 31
Number of included spoutsEF009210
A number
- 32
MaterialEF002169
Choose one value
AluminiumPlasticStainless SteelSteelWoodOther - 33
Halogen FreeEF000025
Yes or no
YesNo - 34
Surface ProtectionEF000139
Choose one value
UntreatedPre-galvanisedGalvanic/electrolytic zinc platedHot Dip GalvanizedOther - 35
ColourEF000007
Choose one value
AluminiumBlackBlueBrownGreenGreyOrangePurple/violetRedStainless Steel - 36
Degree of Protection (IP rating)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 37
Degree of protection (NEMA)EF011959
Choose one value
1233R44X66P1213Other - 38
Cover modelEF009212
Choose one value
NoneConstruction protective coverBlind coverMounting coverCover with hookCover with hook and clampSuitable for snap-in connector (brand specific)Other - 39
Transparent coverEF011401
Yes or no
YesNo - 40
Cover attachmentEF004586
Choose one value
Snap onBayonet latchScrewedHingedCentre mountingOther - 41
SealableEF001454
Yes or no
YesNo - 42
Circuit integrityEF001613
Choose one value
E 30E 60E 90E 120None - 43
With screeningEF005032
Yes or no
YesNo - 44
AirtightEF020032
Yes or no
YesNo - 45
Max. conductor cross sectionEF004969
A number in mm²
- 46
Number of poles of the clampEF008016
A number
- 47
Clamp position fixedEF007889
Yes or no
YesNo - 48
Luminaire hook mountingEF004902
Yes or no
YesNo - 49
NozzleEF008076
Choose one value
Tunnel branch pipeSquare branch pipeDouble nozzlePipe socketOtherNone - 50
Special applicationEF006205
Choose one value
Data/network technologyFire protectionNoise insulationRadiation protectionOtherNone - 51
With partitionEF007973
Yes or no
YesNo - 52
Compliant with BS 4662EFUK0019
Yes or no
YesNo
Codes after each name are ETIM feature codes. Use them, not the names, in product data.