Power cable < 1 kV, for permanent installation

Cables and wires (unassembled). Cable; Energy cable < 1 kV, for permanent installation; House wiring cable; Installation cable for under plaster; In-wall installation cable; Low voltage power cable; Offshore cable; Power cable < 1 kV, for permanent installation; Ship power cable; Shipboard cable; Shipboard low voltage cable; Solar cable

Code:

EC003248

Version:

Group:

Cables and wires (unassembled)

EG000001

Release:

DYNAMIC, ETIM-10.0, ETIM-9.0

Features

01

Conductor material
EF001622 - Alphanumeric

02

Conductor surface
EF010804 - Alphanumeric

03

Nominal cross section conductor (mm²)
EF000060 - Numeric

04

AWG size
EF011789 - Alphanumeric

05

Nominal cross section conductor (AWG) (kcmil)
EF011790 - Numeric

06

Diameter conductor (mm)
EF001621 - Numeric

07

Conductor category
EF001632 - Alphanumeric

08

Conductor resistance at 20 °C (Ohm/km)
EF013551 - Numeric

09

Number of cores
EF001792 - Numeric

10

Twisted cores
EF012612 - Logical

11

Material core insulation
EF000061 - Alphanumeric

12

Specification core insulation
EF011805 - Alphanumeric

13

Core identification according to HD 308 S2
EF013766 - Logical

14

Identification/coding colour core
EF013729 - Alphanumeric

15

Core identification
EF000067 - Alphanumeric

16

Core colour
EF001703 - Alphanumeric

17

With protective conductor
EF007468 - Logical

18

Max. permitted conductor temperature (°C)
EF003803 - Numeric

19

Screen
EF001791 - Logical

20

Drain wire
EF001029 - Logical

21

Lead sheath
EF001027 - Logical

22

Protective barrier
EF003804 - Alphanumeric

23

Armouring/reinforcement
EF001683 - Alphanumeric

24

Material armouring
EF013440 - Alphanumeric

25

Radial water blocking cable
EF011012 - Logical

26

Number of pilot/reduced conductors
EF001697 - Numeric

27

Nominal cross section pilot/reduced conductors (mm²)
EF001696 - Numeric

28

Nominal cross section pilot/reduced conductors (AWG)
EF011792 - Numeric

29

With rodent protection
EF007960 - Logical

30

Material outer sheath
EF001625 - Alphanumeric

31

Specification material outer sheath
EF011806 - Alphanumeric

32

Colour outer sheath
EF001618 - Alphanumeric

33

Cable geometry
EF013532 - Alphanumeric

34

Flame retardant according to IEC 60332-1-2
EF016492 - Logical

35

Flame retardant according to IEC 60332-3-21 (Cat A F/R)
EF016493 - Logical

36

Flame retardant according to IEC 60332-3-22 (Cat A)
EF016494 - Logical

37

Flame retardant according to IEC 60332-3-23 (Cat B)
EF016495 - Logical

38

Flame retardant according to IEC 60332-3-24 (Cat C)
EF016496 - Logical

39

Flame retardant according to IEC 60332-3-25 (Cat D)
EF016497 - Logical

40

Low smoke according to EN IEC 61034-2
EF003799 - Logical

41

Halogen free according to EN IEC 60754-1
EF016498 - Logical

42

Halogen free according to EN IEC 60754-2
EF003792 - Logical

43

Halogen free according to EN IEC 60754-3
EF016500 - Logical

44

Reaction-to-fire according to EN 13501-6: Class
EF011577 - Alphanumeric

45

Reaction-to-fire according to EN 13501-6: Smoke production
EF011578 - Alphanumeric

46

Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
EF011579 - Alphanumeric

47

Reaction-to-fire according to EN 13501-6: Acidity
EF011580 - Alphanumeric

48

Circuit integrity according to IEC 60331-1
EF016616 - Alphanumeric

49

Circuit integrity according to IEC 60331-2
EF016617 - Alphanumeric

50

Circuit integrity according to IEC 60331-3
EF016618 - Alphanumeric

51

Circuit integrity according to EN 50200
EF016621 - Alphanumeric

52

Circuit integrity according to EN 50200 annex E
EF016490 - Logical

53

Oil resistant according to EN IEC 60811-404
EF009770 - Logical

54

Low temperature resistant according to EN 60811-504+505+506
EF009771 - Logical

55

Cable width approximate (mm)
EF003796 - Numeric

56

Cable height approximate (mm)
EF003797 - Numeric

57

Outer diameter approximate (mm)
EF003921 - Numeric

58

Permitted cable outer temperature during assembling/handling (°C)
EF001685 - Range

59

Permitted cable outer temperature after assembling without vibration (°C)
EF001686 - Range

60

Nominal voltage U0 (V)
EF001790 - Numeric

61

Min. permitted bending radius, stationary application/permanent installation (mm)
EF011803 - Numeric

62

Suitable for underground installation
EF003689 - Logical

63

Nominal voltage U (V)
EF001615 - Numeric

64

Nominal equivalent cross section of reinforcement (mm²)
EF013442 - Numeric

65

Shape of conductor
EF001620 - Alphanumeric

66

Suitable as installation cable
EF013771 - Logical

67

Certified for shipboard application
EF013772 - Logical

68

Certified as airport lighting cable
EF013775 - Logical

69

Max. tensile strength during installation (kN)
EF013801 - Numeric

70

Weight (kg/km)
EF000167 - Numeric

71

Number of strands per conductor
EF017357 - Numeric

72

Strand diameter (mm)
EF017358 - Numeric

73

Insulation integrity according to DIN VDE 0472-814
EFDE0050 - Alphanumeric

74

Circuit integrity according to DIN 4102-12
EFDE0051 - Alphanumeric

75

Circuit integrity according to BS 6387 CWZ
EFUK0001 - Logical

76

Circuit integrity according to BS 8434-2
EFUK0004 - Logical

77

Circuit integrity according to BS 8491
EFUK0005 - Alphanumeric
Synonyms

Cable

Energy cable < 1 kV, for permanent installation

House wiring cable

Installation cable for under plaster

In-wall installation cable

Low voltage power cable

Offshore cable

Power cable < 1 kV, for permanent installation

Ship power cable

Shipboard cable

Shipboard low voltage cable

Solar cable