Power cable < 1 kV, for permanent installation EC003248

Published Cables and wires (unassembled) EG000001

Features 67

  1. 1

    Conductor materialEF001622

    Choose one value

    AluminiumCopperOther
  2. 2

    Conductor surfaceEF010804

    Choose one value

    BareSilver-platedTinnedOther
  3. 3

    Nominal cross section conductorEF000060

    A number in mm²

  4. 4

    AWG sizeEF011789

    Choose one value

    00000000001246810
  5. 5

    Nominal cross section conductor (AWG)EF011790

    A number in kcmil

  6. 6

    Diameter conductorEF001621

    A number in mm

  7. 7

    Conductor categoryEF001632

    Choose one value

    Class 1 = solidClass 2 = strandedClass 5 = flexibleClass 6 = very flexible
  8. 8

    Conductor resistance at 20 °CEF013551

    A number in Ohm/km

  9. 9

    Number of coresEF001792

    A number

  10. 10

    Twisted coresEF012612

    Yes or no

    YesNo
  11. 11

    Material core insulationEF000061

    Choose one value

    Ethylene tetrafluoroethylene (ETFE)Fluorinated ethylene propylene (FEP)RubberPaperPolyamide (PA)PolyolefinPolytetrafluoroethylene (PTFE)Polyurethane (PUR)Polyvinyl chloride (PVC)Other
  12. 12

    Specification core insulationEF011805

    Choose one value

    Rubber - ethylene propylene rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Hard grade Ethylene Propylene Rubber (HEPR)Rubber - silicone rubber (SIR)Polyethylene (PE)Crosslinked polyethylene (XLPE)Polypropylene (PP)Other
  13. 13

    Core identification according to HD 308 S2EF013766

    Yes or no

    YesNo
  14. 14

    Identification/coding colour coreEF013729

    Choose one value

    BeigeBlueBrownYellowGreyGreenPurpleOrangePinkRed
  15. 15

    Core identificationEF000067

    Choose one value

    NoneColourNumbersColour and numbersOther
  16. 16

    Core colourEF001703

    Choose one value

    BeigeBlueBrownColourlessYellowGreyGreenGreen/yellowOrangePink
  17. 17

    With protective conductorEF007468

    Yes or no

    YesNo
  18. 18

    Max. permitted conductor temperatureEF003803

    A number in °C

  19. 19

    ScreenEF001791

    Yes or no

    YesNo
  20. 20

    Drain wireEF001029

    Yes or no

    YesNo
  21. 21

    Protective barrierEF003804

    Choose one value

    NoneAl/PEAl/PE/PARubber - ethylene propylene rubber (EPR)Polyurethane (PUR)Polyvinyl chloride (PVC)Other
  22. 22

    Armouring/reinforcementEF001683

    Choose one value

    NoneArmouring tapeWireBraidingLap-screenOther
  23. 23

    Material outer sheathEF001625

    Choose one value

    NoneRubberPolyamide (PA)PolyolefinPolyurethane (PUR)Polyvinyl chloride (PVC)Other
  24. 24

    Specification material outer sheathEF011806

    Choose one value

    Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)Rubber - Polychloroprene (PCP) (no longer used)Polyethylene (PE)Crosslinked polyethylene (XLPE)Other
  25. 25

    Colour outer sheathEF001618

    Choose one value

    BlackBlueBrownColourlessGreenGreyMulti-colouredOrangePinkPurple
  26. 26

    Cable geometryEF013532

    Choose one value

    RoundFlatOther
  27. 27

    Reaction-to-fire according to EN 13501-6: ClassEF011577

    Choose one value

    AcaB1caB2caCcaDcaEcaFcaNone
  28. 28

    Reaction-to-fire according to EN 13501-6: Smoke productionEF011578

    Choose one value

    s1s1as1bs2s3None
  29. 29

    Reaction-to-fire according to EN 13501-6: Flaming droplets/particlesEF011579

    Choose one value

    d0d1d2None
  30. 30

    Reaction-to-fire according to EN 13501-6: AcidityEF011580

    Choose one value

    a1a2a3None
  31. 31

    Halogen free according to EN 60754-1/2 (no longer used)EF009769

    Yes or no

    YesNo
  32. 32

    Flame retardantEF000471

    Choose one value

    NoAccording to IEC/EN 60332-1-2According to IEC/EN 60332-3-24According to IEC/EN 60332-3-22Other
  33. 33

    Low smoke (according to EN 61034-2) (no longer used)EF008027

    Yes or no

    YesNo
  34. 34

    Low temperature resistant according to EN 60811-504+505+506EF009771

    Yes or no

    YesNo
  35. 35

    Oil resistant according to EN IEC 60811-404EF009770

    Yes or no

    YesNo
  36. 36

    Insulation integrityEF003793

    Choose one value

    PH 15PH 30PH 60PH 90PH 120FE 90FE 180None
  37. 37

    Outer diameter approximateEF003921

    A number in mm

  38. 38

    Min. permitted bending radius, stationary application/permanent installationEF011803

    A number in mm

  39. 39

    Nominal equivalent cross section of reinforcementEF013442

    A number in mm²

  40. 40

    Permitted cable outer temperature during assembling/handlingEF001685

    A range, from and to, in °C

  41. 41

    Permitted cable outer temperature after assembling without vibrationEF001686

    A range, from and to, in °C

  42. 42

    Nominal voltage U0EF001790

    A number in V

  43. 43

    Nominal voltage UEF001615

    A number in V

  44. 44

    Circuit integrityEF001613

    Choose one value

    E30E60E90E30 - E60E30 - E90None
  45. 45

    Shape of conductorEF001620

    Choose one value

    RoundSector-shapedOther
  46. 46

    Suitable as installation cableEF013771

    Yes or no

    YesNo
  47. 47

    Certified for shipboard applicationEF013772

    Yes or no

    YesNo
  48. 48

    Suitable as medium-voltage cableEF013773

    Yes or no

    YesNo
  49. 49

    Suitable as high-voltage cableEF013774

    Yes or no

    YesNo
  50. 50

    Certified as airport lighting cableEF013775

    Yes or no

    YesNo
  51. 51

    WeightEF000167

    A number in kg/km

  52. 52

    Circuit integrity according to BS 6387 CWZEFUK0001

    Yes or no

    YesNo
  53. 53

    Circuit integrity according to EN 50200 (no longer used)EFUK0002

    Choose one value

    PH 15PH 30PH 60PH 90PH 120No
  54. 54

    Circuit integrity according to EN 50200 annex E (no longer used)EFUK0003

    Yes or no

    YesNo
  55. 55

    Circuit integrity according to BS 8434-2EFUK0004

    Yes or no

    YesNo
  56. 56

    Circuit integrity according to BS 8491EFUK0005

    Choose one value

    30 min60 min120 minNo
  57. 57

    Circuit integrity according to IEC 60331-3 (no longer used)EFUK0006

    Choose one value

    30 min60 min90 min120 minNo
  58. 58

    Circuit integrity according to IEC 60331-21 (no longer used)EFUK0007

    Yes or no

    YesNo
  59. 59

    Flame retardant according to EN 60332-1-2 (no longer used)EFUK0008

    Yes or no

    YesNo
  60. 60

    Flame retardant according to EN 60332-3-21 (Cat A F/R) (no longer used)EFUK0009

    Yes or no

    YesNo
  61. 61

    Flame retardant according to EN 60332-3-22 (Cat A) (no longer used)EFUK0010

    Yes or no

    YesNo
  62. 62

    Flame retardant according to EN 60332-3-23 (Cat B) (no longer used)EFUK0011

    Yes or no

    YesNo
  63. 63

    Flame retardant according to EN 60332-3-24 (Cat C) (no longer used)EFUK0012

    Yes or no

    YesNo
  64. 64

    Flame retardant according to EN 60332-3-25 (Cat D) (no longer used)EFUK0013

    Yes or no

    YesNo
  65. 65

    Halogen free according to EN 60754-1 (no longer used)EFUK0014

    Yes or no

    YesNo
  66. 66

    Halogen free according to EN 60754-2 (no longer used)EFUK0015

    Yes or no

    YesNo
  67. 67

    Halogen free according to EN 60754-3 (no longer used)EFUK0016

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.