Power cable < 1 kV, for flexible applications EC003250

Published Electrical cables and wiring EG000001

Features 37

  1. 1

    Nominal cross sectional area of conductorEF000060

    A number in mm²

  2. 2

    AWG sizeEF011789

    Choose one value

    00000000001246810
  3. 3

    Nominal cross sectional area of conductor (AWG)EF011790

    A number in kcmil

  4. 4

    Conductor categoryEF001632

    Choose one value

    Class 1 = solidClass 2 = strandedClass 5 = flexibleClass 6 = very flexibleClass D = flexible (no longer used)Class E = very flexible (no longer used)
  5. 5

    Number of coresEF001792

    A number

  6. 6

    Stranding elementEF001617

    Choose one value

    PairsTripleNo
  7. 7

    Core insulation materialEF000061

    Choose one value

    Ethylene tetrafluoroethylene (ETFE)Fluorinated ethylene propylene (FEP)RubberPolyamide (PA)Polyolefin (LSF, LSZH, LS0H)Polytetrafluoroethylene (PTFE)Polyurethane (PUR)Polyvinyl Chloride (PVC)OtherNone
  8. 8

    Specification core insulationEF011805

    Choose one value

    Ethylene Propylene Diene Monomar (EPDM) (no longer used)Rubber - ethylene propylene rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Hard grade Ethylene Propylene Rubber (HEPR)Rubber - silicone rubber (SIR)Polyethylene (PE)Polypropylene (PP)Other
  9. 9

    Core identificationEF000067

    Choose one value

    ColourRingsColour + ringsNumbersOtherNone
  10. 10

    Protective conductor (no longer used)EF001635

    Yes or no

    YesNo
  11. 11

    Individual screen typeEF001623

    Choose one value

    FoilBraidingFoil + braidingOtherNone
  12. 12

    Overall screen typeEF001624

    Choose one value

    FoilBraidingFoil + braidingOtherNone
  13. 13

    Suspension elementEF001794

    Choose one value

    Aramid fibreHempSteelOtherNone
  14. 14

    Sheath materialEF001625

    Choose one value

    RubberPolyamide (PA)Polyolefin (LSF, LSZH, LS0H)Polyurethane (PUR)Polyvinyl Chloride (PVC)Fabric (textile)OtherNone
  15. 15

    Sheath material specificationEF011806

    Choose one value

    Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)Rubber - polychloroprene (CR)Ethylene Propylene Diene Monomar (EPDM) (no longer used)Rubber - ethylene propylene rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - silicone rubber (SIR)Polyethylene (PE)Polypropylene (PP)Other
  16. 16

    Sheath colourEF001618

    Choose one value

    BlueBrownYellowGoldGreyGreenPurple/violetOrangePinkRed
  17. 17

    Torsion resistantEF001687

    Yes or no

    YesNo
  18. 18

    Reaction-to-fire according to EN 13501-6: ClassEF011577

    Choose one value

    AcaB1caB2caCcaDcaEcaFcaNone
  19. 19

    Reaction-to-fire according to EN 13501-6: Smoke productionEF011578

    Choose one value

    s1s1as1bs2s3None
  20. 20

    Reaction-to-fire according to EN 13501-6: Flaming droplets/particlesEF011579

    Choose one value

    d0d1d2None
  21. 21

    Reaction-to-fire according to EN 13501-6: AcidityEF011580

    Choose one value

    a1a2a3None
  22. 22

    Halogen free according to EN 60754-1/2 (no longer used)EF009769

    Yes or no

    YesNo
  23. 23

    Flame retardantEF000471

    Choose one value

    In accordance with IEC/EN 60332-1-2In accordance with IEC/EN 60332-3-24No
  24. 24

    Low smoke (acc. BS EN 61034-2) (no longer used)EF008027

    Yes or no

    YesNo
  25. 25

    Low temperature resistant according to EN 60811-504+505+506EF009771

    Yes or no

    YesNo
  26. 26

    Oil resistant according to IEC 60811-404EF009770

    Yes or no

    YesNo
  27. 27

    ShapeEF000051

    Choose one value

    FlatRound
  28. 28

    Cable width approx.EF003796

    A number in mm

  29. 29

    Cable height approx.EF003797

    A number in mm

  30. 30

    Outer diameter approx.EF003921

    A number in mm

  31. 31

    Min. permitted bending radius, moving application with forced guidanceEF011801

    A number in mm

  32. 32

    Min. permitted bending radius, moving application/free movementEF011802

    A number in mm

  33. 33

    Min. permitted bending radius, stationary application/permanent installationEF011803

    A number in mm

  34. 34

    Permitted cable outer temperature during assembling/handlingEF001685

    A range, from and to, in °C

  35. 35

    Permitted cable outer temperature after assembling without vibrationEF001686

    A range, from and to, in °C

  36. 36

    Nominal voltage U0EF001790

    A number in V

  37. 37

    Nominal voltage UEF001615

    A number in V

Codes after each name are ETIM feature codes. Use them, not the names, in product data.