Power cable < 1 kV, for flexible applications EC003250

A flexible low-voltage power cable designed for dynamic applications. E.g. for cable reels or power cords. But moving application doesn't automatically include the suitability e.g. for cable guide chains.

Published Electrical cables and wiring EG000001

Features 63

  1. 1

    Conductor materialEF001622

    Choose one value

    AluminiumCopperOther
  2. 2

    Conductor surfaceEF010804

    Choose one value

    BareCopper-platedSilver-platedTinnedOther
  3. 3

    AWG sizeEF011789

    Choose one value

    00000000001246810
  4. 4

    Nominal cross sectional area of conductor (AWG)EF011790

    A number in kcmil

  5. 5

    Nominal cross sectional area of conductorEF000060

    A number in mm²

  6. 6

    Conductor categoryEF001632

    Choose one value

    Class 1 = solidClass 2 = strandedClass 5 = flexibleClass 6 = very flexibleClass D = flexible (no longer used)Class E = very flexible (no longer used)
  7. 7

    Number of strands per conductorEF017357

    A number

  8. 8

    Strand diameterEF017358

    A number in mm

  9. 9

    Conductor resistance at 20 °CEF013551

    A number in Ohm/km

  10. 10

    Number of coresEF001792

    A number

  11. 11

    Number of stranding elementsEF001688

    A number

  12. 12

    Individual screen typeEF001623

    Choose one value

    NoneFoilBraidingFoil + braidingOther
  13. 13

    Stranding elementEF001617

    Choose one value

    NoPairsTripleOther
  14. 14

    Overall screen typeEF001624

    Choose one value

    NoneFoilBraidingFoil + braidingOther
  15. 15

    Core insulation materialEF000061

    Choose one value

    Ethylene tetrafluoroethylene (ETFE)Fluorinated ethylene propylene (FEP)RubberPolyamide (PA)Polyolefin (LSF, LSZH, LS0H)Polytetrafluoroethylene (PTFE)Polyurethane (PUR)Polyvinyl Chloride (PVC)Other
  16. 16

    Specification core insulationEF011805

    Choose one value

    EPDMRubber - ethylene propylene rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Hard grade Ethylene Propylene Rubber (HEPR)Rubber - silicone rubber (SIR)Polyethylene (PE)Polypropylene (PP)Other
  17. 17

    Core identification according to HD 308 S2EF013766

    Yes or no

    YesNo
  18. 18

    Core identificationEF000067

    Choose one value

    NoneColourRingsColour + ringsNumbersColours and numbersOther
  19. 19

    With protective conductorEF007468

    Yes or no

    YesNo
  20. 20

    Drain wireEF001029

    Yes or no

    YesNo
  21. 21

    Suspension elementEF001794

    Choose one value

    NoneAramid fibreHempSteelOther
  22. 22

    Sheath materialEF001625

    Choose one value

    NonePolyamide (PA)Polyolefin (LSF, LSZH, LS0H)Polyurethane (PUR)Polyvinyl Chloride (PVC)RubberFabric (textile)Other
  23. 23

    Sheath material specificationEF011806

    Choose one value

    EPDMRubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)Rubber - ethylene propylene rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Polychloroprene (PCP) (no longer used)Rubber - silicone rubber (SIR)Polyethylene (PE)Polypropylene (PP)Other
  24. 24

    Sheath colourEF001618

    Choose one value

    BlackBlueBrownColourlessGoldGreenGreyMulti colourOrangePink
  25. 25

    ScreenEF001791

    Yes or no

    YesNo
  26. 26

    Cable geometryEF013532

    Choose one value

    RoundFlatOther
  27. 27

    Protective barrierEF003804

    Choose one value

    NoneAl/PEAl/PE/PARubber - ethylene propylene rubber (EPR)Polyurethane (PUR)Polyvinyl Chloride (PVC)Other
  28. 28

    Torsion resistantEF001687

    Yes or no

    YesNo
  29. 29

    Armouring/reinforcementEF001683

    Choose one value

    NoneArmouring tapeWireBraidingLap-screenOther
  30. 30

    Material armouringEF013440

    Choose one value

    CopperSteelAluminiumOther
  31. 31

    Flame retardant according to IEC 60332-1-2EF016492

    Yes or no

    YesNo
  32. 32

    Flame retardant according to IEC 60332-3-21 (Cat A F/R)EF016493

    Yes or no

    YesNo
  33. 33

    Flame retardant according to IEC 60332-3-22 (Cat A)EF016494

    Yes or no

    YesNo
  34. 34

    Flame retardant according to IEC 60332-3-23 (Cat B)EF016495

    Yes or no

    YesNo
  35. 35

    Flame retardant according to IEC 60332-3-24 (Cat C)EF016496

    Yes or no

    YesNo
  36. 36

    Flame retardant according to IEC 60332-3-25 (Cat D)EF016497

    Yes or no

    YesNo
  37. 37

    Low smoke according to IEC 61034-2EF003799

    Yes or no

    YesNo
  38. 38

    Halogen free according to IEC 60754-1EF016498

    Yes or no

    YesNo
  39. 39

    Halogen free according to IEC 60754-2EF003792

    Yes or no

    YesNo
  40. 40

    Halogen free according to IEC 60754-3EF016500

    Yes or no

    YesNo
  41. 41

    Reaction-to-fire according to EN 13501-6: ClassEF011577

    Choose one value

    AcaB1caB2caCcaDcaEcaFcaNone
  42. 42

    Reaction-to-fire according to EN 13501-6: Smoke productionEF011578

    Choose one value

    s1s1as1bs2s3None
  43. 43

    Reaction-to-fire according to EN 13501-6: Flaming droplets/particlesEF011579

    Choose one value

    d0d1d2None
  44. 44

    Reaction-to-fire according to EN 13501-6: AcidityEF011580

    Choose one value

    a1a2a3None
  45. 45

    Oil resistant according to IEC 60811-404EF009770

    Yes or no

    YesNo
  46. 46

    Low temperature resistant according to EN 60811-504+505+506EF009771

    Yes or no

    YesNo
  47. 47

    Number of pilot/reduced coresEF001697

    A number

  48. 48

    Nominal cross sectional area of pilot/reduced conductorsEF001696

    A number in mm²

  49. 49

    Nominal cross sectional area of pilot/reduced conductors (AWG)EF011792

    A number

  50. 50

    Cable width approx.EF003796

    A number in mm

  51. 51

    Cable height approx.EF003797

    A number in mm

  52. 52

    Outer diameter approx.EF003921

    A number in mm

  53. 53

    Min. permitted bending radius, moving application with forced guidanceEF011801

    A number in mm

  54. 54

    Min. permitted bending radius, moving application/free movementEF011802

    A number in mm

  55. 55

    Min. permitted bending radius, stationary application/permanent installationEF011803

    A number in mm

  56. 56

    Permitted cable outer temperature during assembling/handlingEF001685

    A range, from and to, in °C

  57. 57

    Permitted cable outer temperature after assembling without vibrationEF001686

    A range, from and to, in °C

  58. 58

    Nominal voltage U0EF001790

    A number in V

  59. 59

    Nominal voltage UEF001615

    A number in V

  60. 60

    Shape of conductorEF001620

    Choose one value

    RoundSector-shapedOther
  61. 61

    Max. tensile strength during installationEF013801

    A number in kN

  62. 62

    Max. conductor temperatureEF003803

    A number in °C

  63. 63

    WeightEF000167

    A number in kg/km