Power cable < 1 kV, for moving application EC003250

A flexible low-voltage power cable designed for dynamic applications. E.g. for cable reels or power cords. But moving application doesn't automatically include the suitability e.g. for cable guide chains.

Published Cables and wires (unassembled) EG000001

Features 63

  1. 1

    Conductor materialEF001622

    Choose one value

    AluminumCopperOther
  2. 2

    Conductor surfaceEF010804

    Choose one value

    BareCopper-platedSilver-platedTinnedOther
  3. 3

    AWG sizeEF011789

    Choose one value

    00000000001246810
  4. 4

    Nominal cross section conductor (AWG)EF011790

    A number in kcmil

  5. 5

    Conductors nominal cross sectionEF000060

    A number in mm²

  6. 6

    Conductor class typeEF001632

    Choose one value

    Class 1 = solidClass 2 = strandedClass 5 = flexibleClass 6 = very flexibleClass D = flexible (no longer used)Class E = very flexible (no longer used)
  7. 7

    Number of strands per conductorEF017357

    A number

  8. 8

    Strand diameterEF017358

    A number in mm

  9. 9

    Conductor resistance at 20 °CEF013551

    A number in Ohm/km

  10. 10

    Number of conductorsEF001792

    A number

  11. 11

    Number of stranding elementsEF001688

    A number

  12. 12

    Shield type over stranding elementEF001623

    Choose one value

    NoneFoilBraidingFoil + braidingOther
  13. 13

    Stranding elementEF001617

    Choose one value

    NoPairsTripleOther
  14. 14

    Cable shieldingEF001624

    Choose one value

    NoneFoilBraidingFoil + braidingOther
  15. 15

    Conductor insulation materialEF000061

    Choose one value

    Ethylene tetrafluoroethylene (ETFE)Fluorinated ethylene propylene (FEP)RubberPolyamide (PA)PolyolefinPolytetrafluoroethylene (PTFE)Polyurethane (PUR)Polyvinyl chloride (PVC)Other
  16. 16

    Conductor insulation material specificationEF011805

    Choose one value

    Ethylene-propylene diene monomer rubber (EPDM)Rubber - Ethylene Propylene Rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Hard grade Ethylene Propylene Rubber (HEPR)Rubber - silicone rubber (SIR)Polyethylene (PE)Polypropylene (PP)Other
  17. 17

    Core identification according to HD 308 S2EF013766

    Yes or no

    YesNo
  18. 18

    Phase identificationEF000067

    Choose one value

    NoneColorRingsColor + ringsNumbersColors and numbersOther
  19. 19

    With protective conductorEF007468

    Yes or no

    YesNo
  20. 20

    Grounding wireEF001029

    Yes or no

    YesNo
  21. 21

    Strength member materialEF001794

    Choose one value

    NoneAramid fibreHempSteelOther
  22. 22

    Outer jacket materialEF001625

    Choose one value

    NonePolyamide (PA)PolyolefinPolyurethane (PUR)Polyvinyl chloride (PVC)RubberFabric (textile)Other
  23. 23

    Outer jacket material specificationEF011806

    Choose one value

    Ethylene-propylene diene monomer rubber (EPDM)Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)Rubber - Ethylene Propylene Rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Polychloroprene (PCP) (no longer used)Rubber - silicone rubber (SIR)Polyethylene (PE)Polypropylene (PP)Other
  24. 24

    Outer jacket colorEF001618

    Choose one value

    BlackBlueBrownColorlessGoldGreenGrayMulti-coloredOrangePink
  25. 25

    ShieldedEF001791

    Yes or no

    YesNo
  26. 26

    Cable shapeEF013532

    Choose one value

    RoundFlatOther
  27. 27

    Protective jacketEF003804

    Choose one value

    NoneAluminum / polyethylene (AI / PE)Aluminium / polyethylene / polyamide (AI / PE / PA)Rubber - Ethylene Propylene Rubber (EPR)Polyurethane (PUR)Polyvinyl chloride (PVC)Other
  28. 28

    Protected against twistingEF001687

    Yes or no

    YesNo
  29. 29

    Armor typeEF001683

    Choose one value

    NoneArmouring tapeWireBraidingLap-screenOther
  30. 30

    Armor materialEF013440

    Choose one value

    CopperSteelAluminumOther
  31. 31

    Flame retardant according to IEC 60332-1-2EF016492

    Yes or no

    YesNo
  32. 32

    Flame retardant according to IEC 60332-3-21 (Cat A F/R)EF016493

    Yes or no

    YesNo
  33. 33

    Flame retardant according to IEC 60332-3-22 (Cat A)EF016494

    Yes or no

    YesNo
  34. 34

    Flame retardant according to IEC 60332-3-23 (Cat B)EF016495

    Yes or no

    YesNo
  35. 35

    Flame retardant according to IEC 60332-3-24 (Cat C)EF016496

    Yes or no

    YesNo
  36. 36

    Flame retardant according to IEC 60332-3-25 (Cat D)EF016497

    Yes or no

    YesNo
  37. 37

    Low smoke according to EN IEC 61034-2EF003799

    Yes or no

    YesNo
  38. 38

    Halogen free according to EN IEC 60754-1EF016498

    Yes or no

    YesNo
  39. 39

    Halogen free according to EN IEC 60754-2EF003792

    Yes or no

    YesNo
  40. 40

    Halogen free according to EN IEC 60754-3EF016500

    Yes or no

    YesNo
  41. 41

    Reaction-to-fire according to EN 13501-6: ClassEF011577

    Choose one value

    AcaB1caB2caCcaDcaEcaFcaNone
  42. 42

    Reaction-to-fire according to EN 13501-6: Smoke productionEF011578

    Choose one value

    s1s1as1bs2s3None
  43. 43

    Reaction-to-fire according to EN 13501-6: Flaming droplets / particlesEF011579

    Choose one value

    d0d1d2None
  44. 44

    Reaction-to-fire according to EN 13501-6: AcidityEF011580

    Choose one value

    a1a2a3None
  45. 45

    Oil resistant (according to EN 60811-404)EF009770

    Yes or no

    YesNo
  46. 46

    Low temperature resistant according to EN 60811-504+505+506EF009771

    Yes or no

    YesNo
  47. 47

    Number of auxiliary conductorsEF001697

    A number

  48. 48

    Auxiliary conductors nominal cross sectionEF001696

    A number in mm²

  49. 49

    Auxiliary conductors nominal cross section (AWG)EF011792

    A number

  50. 50

    Approximate cable widthEF003796

    A number in mm

  51. 51

    Approximate cable heightEF003797

    A number in mm

  52. 52

    Approximate outside diameterEF003921

    A number in mm

  53. 53

    Minimum bend radius, moving application with forced guidanceEF011801

    A number in mm

  54. 54

    Minimum bend radius, moving application / free movementEF011802

    A number in mm

  55. 55

    Minimum bend radius, stationary application / permanent installationEF011803

    A number in mm

  56. 56

    Permitted cable ambient temperature during assemblyEF001685

    A range, from and to, in °C

  57. 57

    Permitted cable ambient temperature after assembly (no vibrations)EF001686

    A range, from and to, in °C

  58. 58

    Nominal voltage U0EF001790

    A number in V

  59. 59

    Nominal voltage UEF001615

    A number in V

  60. 60

    Conductor shapeEF001620

    Choose one value

    RoundSector-shapedOther
  61. 61

    Maximum tensile strength during installationEF013801

    A number in kN

  62. 62

    Maximum permited conductor temperatureEF003803

    A number in °C

  63. 63

    WeightEF000167

    A number in kg/km