Power cable < 1 kV, for moving application EC003250
A flexible low-voltage power cable designed for dynamic applications. E.g. for cable reels or power cords. But moving application doesn't automatically include the suitability e.g. for cable guide chains.
Features 67
- 1
Conductor materialEF001622
Choose one value
AluminumCopperOther - 2
Conductor surfaceEF010804
Choose one value
BareCopper-platedSilver-platedTinnedOther - 3
AWG sizeEF011789
Choose one value
00000000001246810 - 4
Nominal cross section conductor (AWG)EF011790
A number in kcmil
- 5
Conductors nominal cross sectionEF000060
A number in mm²
- 6
Conductor class typeEF001632
Choose one value
Class 1 = solidClass 2 = strandedClass 5 = flexibleClass 6 = very flexible - 7
Number of strands per conductorEF017357
A number
- 8
Strand diameterEF017358
A number in mm
- 9
Conductor resistance at 20 °CEF013551
A number in Ohm/km
- 10
Number of conductorsEF001792
A number
- 11
Twisted coresEF012612
Yes or no
YesNo - 12
Number of stranding elementsEF001688
A number
- 13
Shield type over stranding elementEF001623
Choose one value
NoneBraidingFoilFoil + braidingOther - 14
Stranding elementEF001617
Choose one value
NoPairsTripleOther - 15
Cable shieldingEF001624
Choose one value
NoneBraidingFoilFoil + braidingOther - 16
Conductor insulation materialEF000061
Choose one value
Ethylene tetrafluoroethylene (ETFE)Fluorinated ethylene propylene (FEP)Polyamide (PA)PolyolefinPolytetrafluoroethylene (PTFE)Polyurethane (PUR)Polyvinyl chloride (PVC)RubberOther - 17
Conductor insulation material specificationEF011805
Choose one value
Ethylene-propylene diene monomer rubber (EPDM)Polyethylene (PE)Polypropylene (PP)Rubber - Ethylene Propylene Rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Hard grade Ethylene Propylene Rubber (HEPR)Rubber - silicone rubber (SIR)Other - 18
Core identification according to HD 308 S2EF013766
Yes or no
YesNo - 19
Phase identificationEF000067
Choose one value
NoneColorColor + ringsColors and numbersNumbersRingsOther - 20
With protective conductorEF007468
Yes or no
YesNo - 21
Grounding wireEF001029
Yes or no
YesNo - 22
Strength member materialEF001794
Choose one value
NoneAramid fibreHempSteelOther - 23
Outer jacket materialEF001625
Choose one value
NoneFabric (textile)Polyamide (PA)PolyolefinPolyurethane (PUR)Polyvinyl chloride (PVC)RubberOther - 24
Outer jacket material specificationEF011806
Choose one value
Ethylene-propylene diene monomer rubber (EPDM)Neoprene (CR)Polyethylene (PE)Polypropylene (PP)Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)Rubber - Ethylene Propylene Rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - silicone rubber (SIR)Other - 25
Outer jacket colorEF001618
Choose one value
BlackBlueBrownColorlessGoldGreenGrayMulti-coloredOrangePink - 26
ShieldedEF001791
Yes or no
YesNo - 27
Cable shapeEF013532
Choose one value
FlatRoundOther - 28
Protective jacketEF003804
Choose one value
NoneAluminum / polyethylene (AI / PE)Aluminium / polyethylene / polyamide (AI / PE / PA)Polyurethane (PUR)Polyvinyl chloride (PVC)Rubber - Ethylene Propylene Rubber (EPR)Other - 29
Protected against twistingEF001687
Yes or no
YesNo - 30
Armor typeEF001683
Choose one value
NoneArmouring tapeBraidingLap-screenWireOther - 31
Armor materialEF013440
Choose one value
AluminumCopperSteelOther - 32
Flame retardant according to IEC 60332-1-2EF016492
Yes or no
YesNo - 33
Flame retardant according to IEC 60332-3-21 (Cat A F/R)EF016493
Yes or no
YesNo - 34
Flame retardant according to IEC 60332-3-22 (Cat A)EF016494
Yes or no
YesNo - 35
Flame retardant according to IEC 60332-3-23 (Cat B)EF016495
Yes or no
YesNo - 36
Flame retardant according to IEC 60332-3-24 (Cat C)EF016496
Yes or no
YesNo - 37
Flame retardant according to IEC 60332-3-25 (Cat D)EF016497
Yes or no
YesNo - 38
EF027417
Yes or no
YesNo - 39
Low smoke according to EN IEC 61034-2EF003799
Yes or no
YesNo - 40
Halogen free according to EN IEC 60754-1EF016498
Yes or no
YesNo - 41
Halogen free according to EN IEC 60754-2EF003792
Yes or no
YesNo - 42
Halogen free according to EN IEC 60754-3EF016500
Yes or no
YesNo - 43
Reaction-to-fire according to EN 13501-6: ClassEF011577
Choose one value
AcaB1caB2caCcaDcaEcaFcaNone - 44
Reaction-to-fire according to EN 13501-6: Smoke productionEF011578
Choose one value
s1s1as1bs2s3None - 45
Reaction-to-fire according to EN 13501-6: Flaming droplets / particlesEF011579
Choose one value
d0d1d2None - 46
Reaction-to-fire according to EN 13501-6: AcidityEF011580
Choose one value
a1a2a3None - 47
Suitable for outdoor useEF003532
Yes or no
YesNo - 48
Oil resistant (according to EN 60811-404)EF009770
Yes or no
YesNo - 49
Low temperature resistant according to EN 60811-504+505+506EF009771
Yes or no
YesNo - 50
Number of auxiliary conductorsEF001697
A number
- 51
Auxiliary conductors nominal cross sectionEF001696
A number in mm²
- 52
Auxiliary conductors nominal cross section (AWG)EF011792
A number
- 53
Approximate cable widthEF003796
A number in mm
- 54
Approximate cable heightEF003797
A number in mm
- 55
Approximate outside diameterEF003921
A number in mm
- 56
Minimum bend radius, moving application with forced guidanceEF011801
A number in mm
- 57
Minimum bend radius, moving application / free movementEF011802
A number in mm
- 58
Minimum bend radius, stationary application / permanent installationEF011803
A number in mm
- 59
Permitted cable ambient temperature during assemblyEF001685
A range, from and to, in °C
- 60
Permitted cable ambient temperature after assembly (no vibrations)EF001686
A range, from and to, in °C
- 61
Nominal voltage U0EF001790
A number in V
- 62
Nominal voltage UEF001615
A number in V
- 63
Conductor shapeEF001620
Choose one value
RoundSector-shapedOther - 64
Maximum tensile strength during installationEF013801
A number in kN
- 65
Maximum permited conductor temperatureEF003803
A number in °C
- 66
WeightEF000167
A number in kg/km
- 67
Compliant with UL 1400-2EFNA0043
Yes or no
YesNo
Codes after each name are ETIM feature codes. Use them, not the names, in product data.