Power cable < 1 kV, for moving application EC003250

A flexible low-voltage power cable designed for dynamic applications. E.g. for cable reels or power cords. But moving application doesn't automatically include the suitability e.g. for cable guide chains.

Published Cables and wires (unassembled) EG000001

Features 67

  1. 1

    Conductor materialEF001622

    Choose one value

    AluminumCopperOther
  2. 2

    Conductor surfaceEF010804

    Choose one value

    BareCopper-platedSilver-platedTinnedOther
  3. 3

    AWG sizeEF011789

    Choose one value

    00000000001246810
  4. 4

    Nominal cross section conductor (AWG)EF011790

    A number in kcmil

  5. 5

    Conductors nominal cross sectionEF000060

    A number in mm²

  6. 6

    Conductor class typeEF001632

    Choose one value

    Class 1 = solidClass 2 = strandedClass 5 = flexibleClass 6 = very flexible
  7. 7

    Number of strands per conductorEF017357

    A number

  8. 8

    Strand diameterEF017358

    A number in mm

  9. 9

    Conductor resistance at 20 °CEF013551

    A number in Ohm/km

  10. 10

    Number of conductorsEF001792

    A number

  11. 11

    Twisted coresEF012612

    Yes or no

    YesNo
  12. 12

    Number of stranding elementsEF001688

    A number

  13. 13

    Shield type over stranding elementEF001623

    Choose one value

    NoneBraidingFoilFoil + braidingOther
  14. 14

    Stranding elementEF001617

    Choose one value

    NoPairsTripleOther
  15. 15

    Cable shieldingEF001624

    Choose one value

    NoneBraidingFoilFoil + braidingOther
  16. 16

    Conductor insulation materialEF000061

    Choose one value

    Ethylene tetrafluoroethylene (ETFE)Fluorinated ethylene propylene (FEP)Polyamide (PA)PolyolefinPolytetrafluoroethylene (PTFE)Polyurethane (PUR)Polyvinyl chloride (PVC)RubberOther
  17. 17

    Conductor insulation material specificationEF011805

    Choose one value

    Ethylene-propylene diene monomer rubber (EPDM)Polyethylene (PE)Polypropylene (PP)Rubber - Ethylene Propylene Rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Hard grade Ethylene Propylene Rubber (HEPR)Rubber - silicone rubber (SIR)Other
  18. 18

    Core identification according to HD 308 S2EF013766

    Yes or no

    YesNo
  19. 19

    Phase identificationEF000067

    Choose one value

    NoneColorColor + ringsColors and numbersNumbersRingsOther
  20. 20

    With protective conductorEF007468

    Yes or no

    YesNo
  21. 21

    Grounding wireEF001029

    Yes or no

    YesNo
  22. 22

    Strength member materialEF001794

    Choose one value

    NoneAramid fibreHempSteelOther
  23. 23

    Outer jacket materialEF001625

    Choose one value

    NoneFabric (textile)Polyamide (PA)PolyolefinPolyurethane (PUR)Polyvinyl chloride (PVC)RubberOther
  24. 24

    Outer jacket material specificationEF011806

    Choose one value

    Ethylene-propylene diene monomer rubber (EPDM)Neoprene (CR)Polyethylene (PE)Polypropylene (PP)Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)Rubber - Ethylene Propylene Rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - silicone rubber (SIR)Other
  25. 25

    Outer jacket colorEF001618

    Choose one value

    BlackBlueBrownColorlessGoldGreenGrayMulti-coloredOrangePink
  26. 26

    ShieldedEF001791

    Yes or no

    YesNo
  27. 27

    Cable shapeEF013532

    Choose one value

    FlatRoundOther
  28. 28

    Protective jacketEF003804

    Choose one value

    NoneAluminum / polyethylene (AI / PE)Aluminium / polyethylene / polyamide (AI / PE / PA)Polyurethane (PUR)Polyvinyl chloride (PVC)Rubber - Ethylene Propylene Rubber (EPR)Other
  29. 29

    Protected against twistingEF001687

    Yes or no

    YesNo
  30. 30

    Armor typeEF001683

    Choose one value

    NoneArmouring tapeBraidingLap-screenWireOther
  31. 31

    Armor materialEF013440

    Choose one value

    AluminumCopperSteelOther
  32. 32

    Flame retardant according to IEC 60332-1-2EF016492

    Yes or no

    YesNo
  33. 33

    Flame retardant according to IEC 60332-3-21 (Cat A F/R)EF016493

    Yes or no

    YesNo
  34. 34

    Flame retardant according to IEC 60332-3-22 (Cat A)EF016494

    Yes or no

    YesNo
  35. 35

    Flame retardant according to IEC 60332-3-23 (Cat B)EF016495

    Yes or no

    YesNo
  36. 36

    Flame retardant according to IEC 60332-3-24 (Cat C)EF016496

    Yes or no

    YesNo
  37. 37

    Flame retardant according to IEC 60332-3-25 (Cat D)EF016497

    Yes or no

    YesNo
  38. 38

    EF027417

    Yes or no

    YesNo
  39. 39

    Low smoke according to EN IEC 61034-2EF003799

    Yes or no

    YesNo
  40. 40

    Halogen free according to EN IEC 60754-1EF016498

    Yes or no

    YesNo
  41. 41

    Halogen free according to EN IEC 60754-2EF003792

    Yes or no

    YesNo
  42. 42

    Halogen free according to EN IEC 60754-3EF016500

    Yes or no

    YesNo
  43. 43

    Reaction-to-fire according to EN 13501-6: ClassEF011577

    Choose one value

    AcaB1caB2caCcaDcaEcaFcaNone
  44. 44

    Reaction-to-fire according to EN 13501-6: Smoke productionEF011578

    Choose one value

    s1s1as1bs2s3None
  45. 45

    Reaction-to-fire according to EN 13501-6: Flaming droplets / particlesEF011579

    Choose one value

    d0d1d2None
  46. 46

    Reaction-to-fire according to EN 13501-6: AcidityEF011580

    Choose one value

    a1a2a3None
  47. 47

    Suitable for outdoor useEF003532

    Yes or no

    YesNo
  48. 48

    Oil resistant (according to EN 60811-404)EF009770

    Yes or no

    YesNo
  49. 49

    Low temperature resistant according to EN 60811-504+505+506EF009771

    Yes or no

    YesNo
  50. 50

    Number of auxiliary conductorsEF001697

    A number

  51. 51

    Auxiliary conductors nominal cross sectionEF001696

    A number in mm²

  52. 52

    Auxiliary conductors nominal cross section (AWG)EF011792

    A number

  53. 53

    Approximate cable widthEF003796

    A number in mm

  54. 54

    Approximate cable heightEF003797

    A number in mm

  55. 55

    Approximate outside diameterEF003921

    A number in mm

  56. 56

    Minimum bend radius, moving application with forced guidanceEF011801

    A number in mm

  57. 57

    Minimum bend radius, moving application / free movementEF011802

    A number in mm

  58. 58

    Minimum bend radius, stationary application / permanent installationEF011803

    A number in mm

  59. 59

    Permitted cable ambient temperature during assemblyEF001685

    A range, from and to, in °C

  60. 60

    Permitted cable ambient temperature after assembly (no vibrations)EF001686

    A range, from and to, in °C

  61. 61

    Nominal voltage U0EF001790

    A number in V

  62. 62

    Nominal voltage UEF001615

    A number in V

  63. 63

    Conductor shapeEF001620

    Choose one value

    RoundSector-shapedOther
  64. 64

    Maximum tensile strength during installationEF013801

    A number in kN

  65. 65

    Maximum permited conductor temperatureEF003803

    A number in °C

  66. 66

    WeightEF000167

    A number in kg/km

  67. 67

    Compliant with UL 1400-2EFNA0043

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.