Built-in circulation pump EC010980
A built-in circulation pump is an electrically driven hydronic pump with a built-in motor designed for the continuous circulation of water in heating, cooling, or domestic hot water systems. It is directly integrated into the pipe system and typically mounted vertically in-line supported by the piperun.
Features 67
- 1
Material pump casingEF023038
Choose one value
AluminiumBrassBronzeCast ironCopperStainless steelSteelPolypropylene (PP)Polyurethane (PUR)Polyvinyl chloride (PVC)Other - 2
Material quality pump casingEF023143
Choose one value
Stainless steel 304 (1.4301)Stainless steel 304 L (1.4306)Stainless steel 304 (1.4307)Stainless steel 304 (1.4308)Stainless steel 316 (1.4401)Stainless steel 316 L (1.4404)Stainless steel 316 (1.4408)Stainless steel 316 (1.4409)Stainless steel 316 Ti (1.4571)Stainless steel 321 (1.4541) - 3
Material impeller/pump wheelEF011652
Choose one value
AluminiumBrassBronzeCopperCast ironStainless steelSteelPolypropylene (PP)Polyurethane (PUR)Polyvinyl chloride (PVC)Other - 4
Material quality impeller/pump wheelEF024149
Choose one value
Stainless steel 304 (1.4301)Stainless steel 304 L (1.4306)Stainless steel 304 (1.4307)Stainless steel 304 (1.4308)Stainless steel 316 (1.4401)Stainless steel 316 L (1.4404)Stainless steel 316 (1.4408)Stainless steel 316 (1.4409)Stainless steel 316 Ti (1.4571)Stainless steel 321 (1.4541) - 5
Volume flow rate (BEP)EF014904
A number in m³/h
- 6
Discharge head at flow rate (BEP)EF014905
A number in kPa
- 7
Max. discharge flowEF000991
A number in m³/h
- 8
Max. static heightEF000992
A number in m
- 9
Max. operating pressureEF020449
A number in bar
- 10
Double pumpEF023090
Yes or no
YesNo - 11
Electrical connectionEF003701
Choose one value
CableConnection cable with plugConnecting plugTerminalsOther - 12
Cable lengthEF000536
A number in m
- 13
Rated voltageEF003977
A range, from and to, in V
- 14
Number of phasesEF000351
A number
- 15
FrequencyEF005455
Choose one value
50 Hz60 Hz50/60 HzOther - 16
Nominal currentEF000001
A number in A
- 17
Motor power input (P1) per motorEF012424
A number in kW
- 18
Energy Efficiency Index (EEI)EF026118
A number
- 19
Insulation class according to IECEF023092
Choose one value
BFH - 20
Pump circuitEF023089
Choose one value
TemperatureDaily programWeekly programTemperature/daily programTemperature/weekly programOther - 21
Rotational speedEF001642
A number in 1/min
- 22
Motor speed controlEF020121
Choose one value
NoneBuilt-in (integrated)External (included)External (not included) - 23
Type of speed controlEF020120
Choose one value
Continuously variablePole-reversibleRegulated in fixed steps - 24
CommunicationEF015266
Choose one value
NoneBuilt-in (integrated)PreparedBuilt-in and prepared - 25
Radio standard BluetoothEF007178
Yes or no
YesNo - 26
Radio standard WLAN 802.11EF007179
Yes or no
YesNo - 27
Mobile communications standard 2G (GSM) (no longer used)EF016790
Yes or no
YesNo - 28
Mobile communication standard 3G (UMTS)EF008525
Yes or no
YesNo - 29
Mobile communication standard 4G (LTE)EF016792
Yes or no
YesNo - 30
Mobile communication standard 5GEF016385
Yes or no
YesNo - 31
Interface signal 0-10 V / 2-10 VEF016386
Yes or no
YesNo - 32
Interface signal 0-20 mA / 4-20 mAEF016387
Yes or no
YesNo - 33
Interface PT100 / PT1000 / PTCEF016388
Yes or no
YesNo - 34
Interface Pulse Width Modulation (PWM)EF016389
Yes or no
YesNo - 35
Interface pulse counterEF016390
Yes or no
YesNo - 36
Potential free switch contactEF003626
Yes or no
YesNo - 37
With communication interface RS-485EF007314
Yes or no
YesNo - 38
With communication interface RS-232EF007312
Yes or no
YesNo - 39
Supporting protocol for EtherNet/IPEF007521
Yes or no
YesNo - 40
Supporting protocol for KNXEF003055
Yes or no
YesNo - 41
Supporting protocol for PROFIBUSEF003052
Yes or no
YesNo - 42
Supporting protocol for PROFINET IOEF007525
Yes or no
YesNo - 43
Supporting protocol for CAN/CANOpenEF016391
Yes or no
YesNo - 44
Supporting protocol for Modbus TCPEF016392
Yes or no
YesNo - 45
Supporting protocol for Modbus RTUEF016393
Yes or no
YesNo - 46
Supporting protocol for BACnet MS/TPEF016394
Yes or no
YesNo - 47
Supporting protocol for BACnet IPEF016395
Yes or no
YesNo - 48
Supporting protocol for LON/LONWorksEF016396
Yes or no
YesNo - 49
Supporting protocol for LIN BusEF016397
Yes or no
YesNo - 50
Medium temperature (continuous)EF023182
A range, from and to, in °C
- 51
Ambient temperatureEF002386
A range, from and to, in °C
- 52
Connection inlet sideEF025116
Choose one value
Internal thread cylindrical BSPP-G (ISO 228-1)Internal thread metricInternal thread conical (NPT)Internal thread conical BSPT-Rc (ISO 7-1 / EN 10226-1)Internal thread cylindrical BSPT-Rp (ISO 7-1 / EN 10226-1)Internal thread (NPSM)External thread conical BSPT-R (ISO 7-1 / EN 10226-1)External thread cylindrical BSPP-G (ISO 228-1)External thread metricExternal thread conical (NPT) - 53
Nominal diameter connection inlet sideEF025117
Choose one value
1/2 inch (15)1/4 inch (8)DN 15DN 83/4 inch (20)DN 201 inch (25)DN 251 1/4 inch (32)DN 32 - 54
Outer pipe diameter connection inlet sideEF025503
A number in mm
- 55
Flange compression stage connection inlet sideEF026143
Choose one value
PN 2.5PN 6PN 7PN 9PN 10PN 16PN 25PN 40PN 63PN 100 - 56
Connection standard inlet sideEF014906
Choose one value
AS 2129 Chart EASME B1.20.1ASME B16.1ASME B16.5ASME B16.42EN 1092-1EN 1092-2EN ISO 1452-2ISO 228-1ISO 7005-2 - 57
Connection outlet sideEF025977
Choose one value
Internal thread cylindrical BSPP-G (ISO 228-1)Internal thread metricInternal thread conical (NPT)Internal thread conical BSPT-Rc (ISO 7-1 / EN 10226-1)Internal thread cylindrical BSPT-Rp (ISO 7-1 / EN 10226-1)Internal thread (NPSM)External thread conical BSPT-R (ISO 7-1 / EN 10226-1)External thread cylindrical BSPP-G (ISO 228-1)External thread metricExternal thread conical (NPT) - 58
Nominal diameter connection outlet sideEF025118
Choose one value
1/2 inch (15)1/4 inch (8)DN 15DN 83/4 inch (20)DN 201 inch (25)DN 251 1/4 inch (32)DN 32 - 59
Outer pipe diameter connection outlet sideEF025504
A number in mm
- 60
Flange compression stage connection outlet sideEF026233
Choose one value
PN 2.5PN 6PN 7PN 9PN 10PN 16PN 25PN 40PN 63PN 100 - 61
Connection standard outlet sideEF014907
Choose one value
AS 2129 Chart EASME B1.20.1ASME B16.1ASME B16.5ASME B16.42EN 1092-1EN 1092-2EN ISO 1452-2ISO 228-1ISO 7005-2 - 62
Flange shapeEF001339
Choose one value
RoundQuadrangularOvalOther - 63
Built-in lengthEF004265
A number in mm
- 64
Degree of protection (IP)EF005474
Choose one value
IP00IP05IP10IP11IP12IP20IP21IP22IP23IP24 - 65
DVGW quality mark for waterEFDE0049
Yes or no
YesNo - 66
Approved according to ACSEFFR0008
Yes or no
YesNo - 67
Approved according to WRASEFUK0018
Yes or no
YesNo
Codes after each name are ETIM feature codes. Use them, not the names, in product data.