Heat recovery unit for residential construction EC011285
Features 56
- 1
Housing materialEF001596
Choose one value
Steel coatedPlasticOther - 2
Suitable for wall mountingEF000664
Yes or no
YesNo - 3
Suitable for ceiling mountingEF021180
Yes or no
YesNo - 4
Suitable for floor mountingEF025108
Yes or no
YesNo - 5
Left/right orientation reversibleEF015867
Yes or no
YesNo - 6
Max. air volume at 50 PaEF014851
A number in m³/h
- 7
Max. air volume at 100 PaEF014959
A number in m³/h
- 8
Max. air volume at 150 PaEF014960
A number in m³/h
- 9
Max. air volume at 200 PaEF014961
A number in m³/h
- 10
Max. air volume at 250 PaEF014962
A number in m³/h
- 11
Max. air volume at 300 PaEF014963
A number in m³/h
- 12
Thermal efficiency according to EPN standardEF024363
A number in %
- 13
Power input according to EPN standardEF024359
A number in kW
- 14
Cos phi according to EPN standardEF024360
A number
- 15
With thermal overload protectionEF006233
Yes or no
YesNo - 16
Type of motorEF002735
Choose one value
ACDCElectronically commutated (EC)Other - 17
VoltageEF000213
A number in V
- 18
FrequencyEF000034
A number in Hz
- 19
Number of phasesEF000351
A number
- 20
Electrical connectionEF003701
Choose one value
CableConnecting cable with plug with protective contactPerilex connecting cableTerminalsOther - 21
Energy efficiency classEF000758
Choose one value
A++A+ABCOther - 22
With digital displayEF024362
Yes or no
YesNo - 23
Type of speed controlEF020120
Choose one value
None3 positionsSeparateOther - 24
Supporting protocol for ModbusEF003057
Yes or no
YesNo - 25
With wired control unitEF014706
Yes or no
YesNo - 26
Suitable for wired control unitEF014707
Yes or no
YesNo - 27
Suitable for wireless remote controlEF024361
Yes or no
YesNo - 28
With zone controllerEF014708
Yes or no
YesNo - 29
Suitable for zone controllerEF014709
Yes or no
YesNo - 30
With internal humidity (RH) sensorEF014700
Yes or no
YesNo - 31
Suitable for (extra) humidity (RH) sensorEF014702
Yes or no
YesNo - 32
With internal carbon dioxide (CO2) sensorEF013630
Yes or no
YesNo - 33
Suitable for (extra) carbon dioxide (CO2) sensorEF014699
Yes or no
YesNo - 34
With heating elementEF021913
Yes or no
YesNo - 35
Suitable for central heating boiler connectionEF024407
Yes or no
YesNo - 36
With bypassEF022201
Yes or no
YesNo - 37
With constant pressure controlEF014958
Yes or no
YesNo - 38
With constant volume flow controlEF014957
Yes or no
YesNo - 39
Type of frost protectionEF014956
Choose one value
Frost protection valveHeating elementOther - 40
Nominal duct diameterEF023195
A range, from and to, in mm
- 41
Connections outdoor air sideEF014953
Choose one value
Insert endDuct endInsert-/duct endOther - 42
Connections residential sideEF014954
Choose one value
Insert endDuct endInsert-/duct endOther - 43
Residential connection, undersideEF024364
Yes or no
YesNo - 44
Residential connection, left sideEF024365
Yes or no
YesNo - 45
Residential connection, right sideEF024366
Yes or no
YesNo - 46
Residential connection, topEF024367
Yes or no
YesNo - 47
Roof connection, sideEF024368
Yes or no
YesNo - 48
Roof connection, topEF024369
Yes or no
YesNo - 49
Supply filter according to ISO 16890-1:2016EF013391
Choose one value
ISO CoarseISO ePM10ISO ePM2.5ISO ePM1 - 50
Efficiency supply filter according to ISO 16890-1:2016EF014694
A number in %
- 51
Exhaust filter according to ISO 16890-1:2016EF013390
Choose one value
ISO CoarseISO ePM10ISO ePM2.5ISO ePM1 - 52
Efficiency exhaust filter according to ISO 16890-1:2016EF013389
A number in %
- 53
HeightEF000040
A number in mm
- 54
WidthEF000008
A number in mm
- 55
DepthEF000049
A number in mm
- 56
WeightEF000167
A number in kg
Codes after each name are ETIM feature codes. Use them, not the names, in product data.