Inline circulation pump EC011333

An inline cirulation pump is an electrically driven hydronic pump with an external motor designed for circulating fluids in heating, cooling, or air conditioning systems, where the inlet and outlet are arranged in-line, allowing direct integration into a straight pipe run. These type of pumps are typically mounted horizontally, floor standing, and used in large capacity installations for commercial buildings or industrial installations.

Features 69

  1. 1

    Material pump casingEF023038

    Choose one value

    AluminiumBrassBronzeCast ironCopperStainless steelSteelPolypropylene (PP)Polyurethane (PUR)Polyvinyl chloride (PVC)Other
  2. 2

    Material quality pump casingEF023143

    Choose one value

    Stainless steel 304 (1.4301)Stainless steel 304 L (1.4306)Stainless steel 304 (1.4307)Stainless steel 304 (1.4308)Stainless steel 316 (1.4401)Stainless steel 316 L (1.4404)Stainless steel 316 (1.4408)Stainless steel 316 (1.4409)Stainless steel 316 Ti (1.4571)Stainless steel 321 (1.4541)
  3. 3

    Material impeller/pump wheelEF011652

    Choose one value

    AluminiumBrassBronzeCopperCast ironFibre-reinforced plasticStainless steelPolyphenylene sulfide (PPS)SteelPolypropylene (PP)
  4. 4

    Material quality impeller/pump wheelEF024149

    Choose one value

    Alloyed steelAluminium bronzeBronze (Rg 5)Bronze CuSn10-CC45 (1.0503)Cast iron EN-GJL-150 (GG 15)Cast iron EN-GJL-HB175 (GG-170-HB)Cast iron EN-GJL-200 (GG 20)Cast iron EN-GJL-250 (GG 25)Cast iron EN-GJS-400-15 (GGG 40)
  5. 5

    Volume flow rate (BEP)EF014904

    A number in m³/h

  6. 6

    Discharge head at flow rate (BEP)EF014905

    A number in kPa

  7. 7

    Max. discharge flowEF000991

    A number in m³/h

  8. 8

    Max. static heightEF000992

    A number in m

  9. 9

    Max. operating pressureEF020449

    A number in bar

  10. 10

    Double pumpEF023090

    Yes or no

    YesNo
  11. 11

    Electrical connectionEF003701

    Choose one value

    CableConnection cable with plugTerminalsOther
  12. 12

    Cable lengthEF000536

    A number in m

  13. 13

    Rated voltageEF003977

    A range, from and to, in V

  14. 14

    Number of phasesEF000351

    A number

  15. 15

    FrequencyEF005455

    Choose one value

    50 Hz60 Hz50/60 HzOther
  16. 16

    Nominal currentEF000001

    A number in A

  17. 17

    Motor power input (P1) per motorEF012424

    A number in kW

  18. 18

    Motor power output (P2) per motorEF012425

    A number in kW

  19. 19

    Minimum Efficiency Index (MEI)EF013710

    A number

  20. 20

    Insulation class according to IECEF023092

    Choose one value

    BFH
  21. 21

    Rotational speedEF001642

    A number in 1/min

  22. 22

    Motor speed controlEF020121

    Choose one value

    NoneBuilt-in (integrated)External (included)External (not included)
  23. 23

    Type of speed controlEF020120

    Choose one value

    Continuously variablePole-reversibleRegulated in fixed stepsOther
  24. 24

    Motor with extended shaftEF023093

    Yes or no

    YesNo
  25. 25

    CommunicationEF015266

    Choose one value

    NoneBuilt-in (integrated)PreparedBuilt-in and prepared
  26. 26

    Radio standard BluetoothEF007178

    Yes or no

    YesNo
  27. 27

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  28. 28

    Mobile communications standard 2G (GSM) (no longer used)EF016790

    Yes or no

    YesNo
  29. 29

    Mobile communication standard 3G (UMTS)EF008525

    Yes or no

    YesNo
  30. 30

    Mobile communication standard 4G (LTE)EF016792

    Yes or no

    YesNo
  31. 31

    Mobile communication standard 5GEF016385

    Yes or no

    YesNo
  32. 32

    Interface signal 0-10 V / 2-10 VEF016386

    Yes or no

    YesNo
  33. 33

    Interface signal 0-20 mA / 4-20 mAEF016387

    Yes or no

    YesNo
  34. 34

    Interface PT100 / PT1000 / PTCEF016388

    Yes or no

    YesNo
  35. 35

    Interface Pulse Width Modulation (PWM)EF016389

    Yes or no

    YesNo
  36. 36

    Interface pulse counterEF016390

    Yes or no

    YesNo
  37. 37

    Potential free switch contactEF003626

    Yes or no

    YesNo
  38. 38

    With communication interface RS-485EF007314

    Yes or no

    YesNo
  39. 39

    With communication interface RS-232EF007312

    Yes or no

    YesNo
  40. 40

    Supporting protocol for EtherNet/IPEF007521

    Yes or no

    YesNo
  41. 41

    Supporting protocol for KNXEF003055

    Yes or no

    YesNo
  42. 42

    Supporting protocol for PROFIBUSEF003052

    Yes or no

    YesNo
  43. 43

    Supporting protocol for PROFINET IOEF007525

    Yes or no

    YesNo
  44. 44

    Supporting protocol for CAN/CANOpenEF016391

    Yes or no

    YesNo
  45. 45

    Supporting protocol for Modbus TCPEF016392

    Yes or no

    YesNo
  46. 46

    Supporting protocol for Modbus RTUEF016393

    Yes or no

    YesNo
  47. 47

    Supporting protocol for BACnet MS/TPEF016394

    Yes or no

    YesNo
  48. 48

    Supporting protocol for BACnet IPEF016395

    Yes or no

    YesNo
  49. 49

    Supporting protocol for LON/LONWorksEF016396

    Yes or no

    YesNo
  50. 50

    Supporting protocol for LIN BusEF016397

    Yes or no

    YesNo
  51. 51

    Medium temperature (continuous)EF023182

    A range, from and to, in °C

  52. 52

    Ambient temperatureEF002386

    A range, from and to, in °C

  53. 53

    Connection inlet sideEF025116

    Choose one value

    Internal thread cylindrical BSPP-G (ISO 228-1)Internal thread metricInternal thread conical (NPT)Internal thread conical BSPT-Rc (ISO 7-1 / EN 10226-1)Internal thread cylindrical BSPT-Rp (ISO 7-1 / EN 10226-1)Internal thread (NPSM)External thread conical BSPT-R (ISO 7-1 / EN 10226-1)External thread cylindrical BSPP-G (ISO 228-1)External thread metricExternal thread conical (NPT)
  54. 54

    Nominal diameter connection inlet sideEF025117

    Choose one value

    3/4 inch (20)1/4 inch (8)DN 20DN 81/2 inch (15)DN 151 inch (25)DN 251 1/4 inch (32)DN 32
  55. 55

    Outer pipe diameter connection inlet sideEF025503

    A number in mm

  56. 56

    Flange compression stage connection inlet sideEF026143

    Choose one value

    PN 2.5PN 6PN 7PN 9PN 10PN 16PN 25PN 40PN 63PN 100
  57. 57

    Connection standard inlet sideEF014906

    Choose one value

    AS 2129 Chart EASME B1.20.1ASME B16.1ASME B16.5ASME B16.42EN 1092-1EN 1092-2EN ISO 1452-2ISO 228-1ISO 7005-2
  58. 58

    Connection outlet sideEF025977

    Choose one value

    Internal thread cylindrical BSPP-G (ISO 228-1)Internal thread metricInternal thread conical (NPT)Internal thread conical BSPT-Rc (ISO 7-1 / EN 10226-1)Internal thread cylindrical BSPT-Rp (ISO 7-1 / EN 10226-1)Internal thread (NPSM)External thread conical BSPT-R (ISO 7-1 / EN 10226-1)External thread cylindrical BSPP-G (ISO 228-1)External thread metricExternal thread conical (NPT)
  59. 59

    Nominal diameter connection outlet sideEF025118

    Choose one value

    3/4 inch (20)1/4 inch (8)DN 20DN 81/2 inch (15)DN 151 inch (25)DN 251 1/4 inch (32)DN 32
  60. 60

    Outer pipe diameter connection outlet sideEF025504

    A number in mm

  61. 61

    Flange compression stage connection outlet sideEF026233

    Choose one value

    PN 2.5PN 6PN 7PN 9PN 10PN 16PN 25PN 40PN 63PN 100
  62. 62

    Connection standard outlet sideEF014907

    Choose one value

    AS 2129 Chart EASME B1.20.1ASME B16.1ASME B16.5ASME B16.42EN 1092-1EN 1092-2EN ISO 1452-2ISO 228-1ISO 7005-2
  63. 63

    Flange shapeEF001339

    Choose one value

    RoundQuadrangularOvalOther
  64. 64

    Built-in lengthEF004265

    A number in mm

  65. 65

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP05IP10IP12IP20IP21IP22IP23IP24IP25
  66. 66

    Self-primingEF020038

    Yes or no

    YesNo
  67. 67

    Explosion-proofEF004663

    Yes or no

    YesNo
  68. 68

    Standard motorEF014908

    Yes or no

    YesNo
  69. 69

    Motor efficiency classEF014979

    Choose one value

    IE1IE2IE3IE4IE5Other

Codes after each name are ETIM feature codes. Use them, not the names, in product data.