Emergency luminaire EC001957

A backup lighting fixture that activates during power failures.

Features 68

  1. 1

    Mounting methodEF000003

    Choose one value

    Bottom mountingBuilt-inBusbar adaptorCeiling surface mountingChainPendantSupporting bracketSurface mounting/recessed mountingWall surface mountedWall surface mounting/ceiling surface mountingOther
  2. 2

    FunctionEF000030

    Choose one value

    Escape route lightingEscape route lighting/signageEscape route signage
  3. 3

    Suitable for labelling typeEF001277

    Choose one value

    Acrylic plateInsert sheet/plateStickerOther
  4. 4

    Type of indicatorEF001278

    Choose one value

    Double-sidedFour-sidedSingle-sidedSingle/double-sidedThree-sided
  5. 5

    With pictogramEF011099

    Yes or no

    YesNo
  6. 6

    Suitable for standby switchingEF017055

    Yes or no

    YesNo
  7. 7

    Suitable for continuous circuitEF017056

    Yes or no

    YesNo
  8. 8

    With remote switch connectionEF007947

    Yes or no

    YesNo
  9. 9

    Remote control includedEF000483

    Yes or no

    YesNo
  10. 10

    Emergency function monitoring systemEF018921

    Choose one value

    Automatic self testTest buttonTest button/automatic self testOtherNone
  11. 11

    Emergency power supply systemEF018918

    Choose one value

    Central (central battery)Central (central battery) and peripheral (individual battery)Peripheral (individual battery)None
  12. 12

    Battery technologyEF004351

    Choose one value

    LeadLithium-ionNiCdNiMHOther
  13. 13

    Type of lithium-ion batteryEF019181

    Choose one value

    Lithium cobalt oxide (LiCoO2)Lithium iron phosphate (LiFePO4)Other
  14. 14

    With heating element for batteryEF019180

    Yes or no

    YesNo
  15. 15

    Lamp typeEF002423

    Choose one value

    Compact fluorescent lampFluorescent lampHV halogen lampIncandescent lampLED exchangeableLED not exchangeableLV halogen lampOther
  16. 16

    With light sourceEF005905

    Yes or no

    YesNo
  17. 17

    Suitable for number of light sourcesEF006436

    A number

  18. 18

    Lamp holderEF000048

    Choose one value

    2G72G102G112G13B15dB22dBA9sE10E14E27
  19. 19

    Number of lighting headsEF004258

    A number

  20. 20

    Housing materialEF001596

    Choose one value

    AluminiumPlasticStainless steelSteelOther
  21. 21

    RAL-number housingEF012502

    A number

  22. 22

    Housing colourEF000136

    Choose one value

    AluminiumAnthraciteBeigeBlackBlueBrassBronzeBrownChromeColourless
  23. 23

    Cover materialEF004284

    Choose one value

    Glass, matt/satinizedGlass, opalGlass, structuredGlass, transparentPlastic, matt/satinizedPlastic, opalPlastic, structuredPlastic, transparentOtherWithout cover
  24. 24

    Voltage typeEF000187

    Choose one value

    ACDCAC/DC
  25. 25

    Nominal voltageEF005127

    A range, from and to, in V

  26. 26

    Nominal currentEF009345

    A range, from and to, in mA

  27. 27

    Type of control gearEF000381

    Choose one value

    Electronic ballastElectronic transformerLED operating device current-controlledLED operating device voltage-controlledLow-loss ballast compensatedLow-loss ballast inductiveMagnetic transformerNot required
  28. 28

    Exchangeable control gearEF016286

    Yes or no

    YesNo
  29. 29

    Light distributorEF012170

    Choose one value

    Diffuser lens/optic/panelFocal lensReflectorRefractor lensOtherNone
  30. 30

    Max. number of luminaires per miniature circuit breaker B16 (MCB)EF015534

    A number

  31. 31

    Energy efficiency class of the light source according to 2019/2015/EUEF016835

    Choose one value

    ABCDEFGNot required
  32. 32

    Max. number of luminaires per miniature circuit breaker C16 (MCB)EF015533

    A number

  33. 33

    Rated lifetime L70/B50 at 25 °CEF011870

    A number in h

  34. 34

    Lumen maintenance at median useful life of 50,000 h at 25 °C ambient (tq)EF015687

    A number in %

  35. 35

    Lumen maintenance at median useful life of 100,000 h at 25 °C ambient (tq)EF015689

    A number in %

  36. 36

    Failure rate at median useful life of 50,000 h at 25 °C ambient (tq)EF015691

    A number in %

  37. 37

    Failure rate at median useful life of 100,000 h at 25 °C ambient (tq)EF015693

    A number in %

  38. 38

    Constant light output (CLO)EF009482

    Yes or no

    YesNo
  39. 39

    Degree of protection (NEMA)EF011959

    Choose one value

    1233R44X1213Other
  40. 40

    Impact strengthEF004293

    Choose one value

    IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09
  41. 41

    Protection class according to IEC 61140EF000004

    Choose one value

    IIIIIINone
  42. 42

    Luminaire with limited surface temperature, sign "D“ according to EN 60598-2-24EF006420

    Yes or no

    YesNo
  43. 43

    Ambient temperatureEF002386

    A range, from and to, in °C

  44. 44

    Luminous flux in emergency modeEF008731

    A number in lm

  45. 45

    Rated luminous flux according to IEC 62722-2- 1EF018714

    A range, from and to, in lm

  46. 46

    Max. system powerEF009347

    A number in W

  47. 47

    Power consumption in emergency modeEF018920

    A number in W

  48. 48

    Luminous flux in standby modeEF011954

    A number in lm

  49. 49

    Colour temperatureEF009346

    A range, from and to, in K

  50. 50

    Power factorEF025740

    A number

  51. 51

    Recognition distanceEF008732

    A number in m

  52. 52

    Nominal operation timeEF012518

    A range, from and to, in h

  53. 53

    Flickering value Pst LMEF015827

    A number

  54. 54

    Stroboscope effect value SVMEF015828

    A number

  55. 55

    WidthEF000008

    A number in mm

  56. 56

    HeightEF000040

    A number in mm

  57. 57

    DepthEF000049

    A number in mm

  58. 58

    Outer diameterEF000015

    A number in mm

  59. 59

    Built-in widthEF000846

    A number in mm

  60. 60

    Built-in depthEF000218

    A number in mm

  61. 61

    Built-in heightEF000332

    A number in mm

  62. 62

    Built-in diameterEF000943

    A number in mm

  63. 63

    Type of wiringEF011868

    Choose one value

    EndingLoop-through wiring includedSuitable for loop-through wiring
  64. 64

    Number of polesEF001391

    A number

  65. 65

    Conductor cross sectionEF000085

    A number in mm²

  66. 66

    Connection typeEF000124

    Choose one value

    BusBusbar adaptorCableConnection cable with plugInsulation displacement connectorPlugPush-in clampScrewed terminalOther
  67. 67

    Connectable conductor cross sectionEF008200

    A range, from and to, in mm²

  68. 68

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30

Codes after each name are ETIM feature codes. Use them, not the names, in product data.