Emergency luminaire EC001957
Features 63
- 1
Mounting methodEF000003
Choose one value
Wall surface mountedCeiling surface mountingWall surface mounting/ceiling surface mountingBottom mountingSupporting bracketPendantBuilt-inSurface mounting/recessed mountingChain - 2
FunctionEF000030
Choose one value
Escape route lightingEscape route signageEscape route lighting/signage - 3
Suitable for labelling typeEF001277
Choose one value
StickerInsert sheet/plateAcrylic plateOther - 4
Type of indicatorEF001278
Choose one value
Single-sidedSingle/double-sidedDouble-sidedThree-sidedFour-sided - 5
With pictogramEF011099
Yes or no
YesNo - 6
Monitoring equipment (no longer used)EF008091
Choose one value
Test buttonAutomatic self testSafety module for monitoring (central feeded system)OtherNone - 7
Suitable for standby switchingEF017055
Yes or no
YesNo - 8
Suitable for continuous circuitEF017056
Yes or no
YesNo - 9
With remote switch connectionEF007947
Yes or no
YesNo - 10
Remote control includedEF000483
Yes or no
YesNo - 11
Power supply system (no longer used)EF000233
Choose one value
Central (central battery)Peripheral (individual battery) - 12
Battery technologyEF004351
Choose one value
LeadLithium-ionNiCdNiMHOther - 13
Lamp typeEF002423
Choose one value
Incandescent lampLV halogen lampHV halogen lampCompact fluorescent lampLED exchangeableLED not exchangeableFluorescent lampOther - 14
With light sourceEF005905
Yes or no
YesNo - 15
Suitable for number of light sourcesEF006436
A number
- 16
Lamp holderEF000048
Choose one value
2G72G102G112G13B15dB22dBA9sE10E14E27 - 17
Number of lighting headsEF004258
A number
- 18
Housing materialEF001596
Choose one value
AluminiumSteelStainless steelPlasticOther - 19
RAL-number housingEF012502
A number
- 20
Housing colourEF000136
Choose one value
AluminiumAnthraciteBeigeBlueBrownBronzeChromeColourlessStainless steelYellow - 21
Cover materialEF004284
Choose one value
Glass, opalGlass, structuredGlass, transparentGlass, matt/satinizedPlastic, opalPlastic, structuredPlastic, transparentPlastic, matt/satinizedOtherWithout cover - 22
Voltage typeEF000187
Choose one value
ACDCAC/DC - 23
Nominal voltageEF005127
A range, from and to, in V
- 24
Nominal currentEF009345
A range, from and to, in mA
- 25
Type of control gearEF000381
Choose one value
Electronic transformerElectronic ballastLow-loss ballast inductiveLow-loss ballast compensatedLED operating device voltage-controlledLED operating device current-controlledMagnetic transformerNot required - 26
Exchangeable control gearEF016286
Yes or no
YesNo - 27
Light distributorEF012170
Choose one value
Diffuser lens/optic/panelFocal lensReflectorRefractor lensOtherNone - 28
Max. number of luminaires per miniature circuit breaker B16 (MCB)EF015534
A number
- 29
Energy efficiency class of the light source according to 2019/2015/EUEF016835
Choose one value
ABCDEFGNot required - 30
Max. number of luminaires per miniature circuit breaker C16 (MCB)EF015533
A number
- 31
Rated lifetime L70/B50 at 25 °CEF011870
A number in h
- 32
Lumen maintenance at median useful life of 50,000 h at 25 °C ambient (tq)EF015687
A number in %
- 33
Lumen maintenance at median useful life of 100,000 h at 25 °C ambient (tq)EF015689
A number in %
- 34
Failure rate at median useful life of 50,000 h at 25 °C ambient (tq)EF015691
A number in %
- 35
Failure rate at median useful life of 100,000 h at 25 °C ambient (tq)EF015693
A number in %
- 36
Constant light output (CLO)EF009482
Yes or no
YesNo - 37
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 38
Degree of protection (NEMA)EF011959
Choose one value
1233R44X1213Other - 39
Impact strengthEF004293
Choose one value
IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09 - 40
Protection class according to IEC 61140EF000004
Choose one value
IIIIIINone - 41
Luminaire with limited surface temperature, sign "D“ according to EN 60598-2-24EF006420
Yes or no
YesNo - 42
Rated ambient temperature according to IEC 62722-2-1EF012090
A range, from and to, in °C
- 43
Max. system powerEF009347
A number in W
- 44
Rated luminous flux according to IEC 62722-2-1 (no longer used)EF009349
A number in lm
- 45
Luminous flux in standby modeEF011954
A number in lm
- 46
Colour temperatureEF009346
A range, from and to, in K
- 47
Power factorEF025740
A number
- 48
Recognition distanceEF008732
A number in m
- 49
Nominal operation timeEF012518
A range, from and to, in h
- 50
Flickering value Pst LMEF015827
A number
- 51
Stroboscope effect value SVMEF015828
A number
- 52
WidthEF000008
A number in mm
- 53
Height/depthEF001456
A number in mm
- 54
LengthEF001438
A number in mm
- 55
Outer diameterEF000015
A number in mm
- 56
Built-in widthEF000846
A number in mm
- 57
Built-in height/depthEF023518
A number in mm
- 58
Built-in lengthEF004265
A number in mm
- 59
Built-in diameterEF000943
A number in mm
- 60
Type of wiringEF011868
Choose one value
Suitable for loop-through wiringLoop-through wiring includedEnding - 61
Number of polesEF001391
A number
- 62
Conductor cross sectionEF000085
A number in mm²
- 63
Connection typeEF000124
Choose one value
Unpreassembled connection cableConnection cable with mains plug (2P+E)Connection cable with EuroplugConnection cable systemplugScrew connectionPlug-in connectionSoldering connectionOther
Codes after each name are ETIM feature codes. Use them, not the names, in product data.